uPrint/uPrint SE Service Manual
5-13
24.
Measure and record the distance from the outside edge of the small bump on circle G to
the outside edge of circle D. See
Figure 5-295: Measuring distances from outside edges of D and G
25.
Measure and record the diameter of circle D along the center line between A and G. See
Figure 5-296: Measuring diameter of circle D
26.
Add the lengths derived from steps 24 and 25 (A-D and D-G) and then subtract the width
of circle D derived from step 26. Record this total as “GLF”
27.
Enter the Service Calibration menu by pressing the following button sequence on the
display panel:
3,2,3,3,1
. See
28.
Press the
Edit Configuration
button.
29.
Press the
GLeft
button. Enter the value recorded from step
Increment
,
Decrement
and
Next Digit
buttons.
30.
When finished, press
Done...
31.
Press the
GRight
button. Enter the value recorded from step
by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
32.
When finished, press
Done...
Note:
The value for GLeft must be between 5.250 and 5.750, the
Done...
button will
not appear until the value is within the acceptable range.
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...