uPrint/uPrint SE Service Manual
5-3
Entering Z Calibration values manually (Firmware version 9.1 or newer)
Z tip to base (ZT2B)
ZT2B is the Z distance from the support tip to the Z substrate sensor activation point.
If unable to
calibrate automatically, this value may need to be set to default in order to proceed with automatic
calibration. The default value is -0.0700”.
1.
While the printer is at
Idle
, enter standby mode by pressing the
Standby...
button.
2.
Enter the Service Calibration menu by pressing the following button sequence on the
display panel:
3,2,3,3,1
. See
Figure 5-278: Service Calibration button sequence
3.
Press the
Edit Configuration
button.
4.
Press the
Next...
button.
5.
Press the
Next...
button.
6.
Press the
ZT2B
(Z tip to base) button.
7.
Enter the calibration value by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
8.
When finished, press
Done...
9.
Press the
Next...
button.
10.
Press the
Save and reboot
button.
11.
The printer will reboot and return to idle.
12.
Perform automatic Z calibration. See
Note:
The value for ZT2B must be between -0.1500” and 0.0000”.
Button 0
Button 1
Button 2
Button 3
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...