Names and Functions of Parts of the Control Panel
Name
Description
2nd row
• Use this to select the cross-point of the
bus that is specified with the 1st row
buttons.
a) b)
• If the utility/shotbox function is selected
with the 1st row buttons, use this to
recall the register or to execute the
function.
Background A
row
Use this to select the signal as the
current background video on this M/E
bank or PGM/PST bank.
Background B
row
Use this to select the signal as the
background video after the transition on
this M/E bank or PGM/PST bank.
Name
Description
INH SET
(inhibit set)
Disables button operation.
To inhibit operation for a button,
press and hold the button
assigned with [INH SET], and
press the cross-point button
whose operation you wish to
inhibit.
XPT HOLD
(cross-point hold)
Recalls a keyframe or snapshot
while maintaining the current
cross-point selection conditions.
Available for background A row
and background B row.
The following function blocks can
be enabled, depending on
settings in the Setup menu.
• Background A and B rows
• Key bus
• Utility bus
• DME external video bus (MVS-
6520/6530/3000A only)
PRE MCRO
(pre-macro)
Sets a macro attachment in pre-
macro mode.
When setting to macro-only mode,
this button is used in combination
with the user preference button on
the menu panel with the
“Macro
Only
Set” assignment. This mode
can also be set by pressing the
[PRE MCRO] and [POST MCRO]
buttons simultaneously.
POST MCRO
(post-macro)
Sets a macro attachment in post-
macro mode.
When setting to macro-only mode,
this button is used in combination
with the user preference button on
the menu panel with the
“Macro
Only
Set” assignment. This mode
can also be set by pressing the
[PRE MCRO] and [POST MCRO]
buttons simultaneously.
Ch
a
p
te
r 2
Na
m
e
s
and
Fun
c
ti
o
n
s
of
P
a
rts
2nd row
Background A row
Background B row
1) MVS-6520/6530/3000A only
2) MKS-6570 only
3) MVE-8000A/9000 only
For details about assignments,
Function to 1st Row Buttons” (p. 340)
Utility/shotbox function
Assign the function of the [UTIL/SBOX] button, and use
for utility/shotbox operations.
When you turn on the button to which [UTIL/SBOX] is
assigned, the buttons in the cross-point control block will
be used for utility/shotbox operations.
For details,
“Executing a Shotbox Function with
Cross-Point Buttons in the 2nd Row” (p. 280)
Assignable buttons
a)
You can select the source signal of the key bus by selecting the cross-point
while holding down the button to which any of KEY1 to KEY4 or DSK1
to DSK4 is assigned in the 1st row.
b)
You can select the image on the reverse side of the currently viewed DME
image by selecting the cross-point while holding down the button to which
any of DME1 V/K, DME2 V/K, or DME5 V/K to DME8 V/K is assigned
in the 1st row (DME1 V/K and DME2 V/K using MKS-6570 only, and
DME5 V/K to DME8 V/K using MVE-8000A/9000 only).
Cross-point button numbers
Cross-point buttons are respectively numbered
Assigning signals to buttons
You can assign a signal to each button using the Setup
menu.
For details,
“Cross-Point Settings” (p. 329)
Visual indications on cross-point buttons
For details,
“Colors of lit cross-point buttons” (p. 63)
b
1st row
This selects a key bus, AUX bus, or function.
You can assign the following buses, functions, and buttons
in the Setup menu.
•
KEY1 to KEY4, DSK1 to DSK4, UTIL1, EXT DME
1)
,
EDIT PVW, AUX1 to AUX24, FMS1, FMS2,
DME1 V/K
2)
, DME2 V/K
2)
, DME5 V/K to
DME8 V/K
3)
•
Utility/shotbox function
•
[INH SET], [XPT HOLD], [PRE MCRO], [POST
MCRO], [MCRO ATTCH ENBL], [KEY], [1ST ROW
DSPLY], [2ND ROW DSPLY], [SHIFT] buttons