cross-points buttons after displaying the menu for
which you want to create a shortcut to assign the
menu shortcut. To finish the assignment, press
[Menu Shortcut] again.
If [Utility Command] is selected:
Select the
command you want to assign on the right side of
the status area.
No.
Parameter
Adjustment
3
Command
Command selection
4
GPI No
GPI number
a)
a) SWR GPI Test Fire, Panel GPI Test Fire, and DCU GPI Test Fire
commands only.
If [Macro Recall] is selected:
Select the macro
register you want to assign.
No.
Parameter
Adjustment
3
Macro
Macro register selection
If [Shotbox Recall] is selected:
Select the shotbox
register you want to assign.
No.
Parameter
Adjustment
3
Shotbox
Shotbox register selection
5
If you selected a function other than [Menu Shortcut]
in step
3
, press [Action Set].
This assigns the selected action, which is reflected in
the status area.
To cancel an assignment
Select the button, then press [Clear].
To display register names in the
“Utility
Command” column
If in step
3
you select [Macro Recall] or [Shotbox Recall],
press [Reg Name Display] to select whether or not register
names appear in the “Utility Command” column.
For details about utility commands,
commands and user preference button status” (p. 335)
Note that the “System Manager Enbl” command cannot be
assigned to cross-point buttons in the 2nd row.
Interfacing with External
Devices
Making Control Panel GPI Input
Settings
You can set the GPI input ports and trigger type, and make
the action settings.
1
Open the Engineering Setup >Panel >Device Interface
>GPI Input menu (7325.1).
2
Select the port to set.
3
In the <Trigger Type> group, select the trigger type.
(Rising Edge):
Applies the trigger on the rising
edge of an input pulse.
(Falling Edge):
Applies the trigger on the falling
edge of an input pulse.
(Any Edge):
Applies the trigger on a change in
the polarity of the input signal.
(Level):
Carries out the specified operation when
the input is low or high.
No Operation:
Applies no trigger on an input pulse.
4
In the <Target> group, select the action block.
M/E-1 and P/P:
Sets an action for the M/E or PGM/
PST bank.
Common/Setup:
Sets an action for something other
than the above, or a setup action.
5
Select the action to set.
6
Press [Action Set] to confirm the action selection.
Selectable actions for various trigger types
•
When the trigger type is other than “Level”
(The x in M/E-x is the M/E bank number, the x in DSKx
is the DSK number, and the x in Keyx is the key
number).
When Target is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, Keyx SS ? Recall
When Target is P/P: Cut, Auto Trans, DSKx Cut, DSKx
Auto Trans, DSKx SS ? Recall, FTB Auto Trans,
FTB Cut
When Target is Common/Setup: Master SS ? Recall,
Master Effect ? Recall, SS ? Recall, Effect ? Recall,
Effect ? Recall & Run, KF Run, KF Stop, KF
Rewind, FM Src1 Frame Freeze, FM Src1 Field
Freeze, FM Src1 Freeze Off, FM Src2 Frame Freeze,
FM Src2 Field Freeze, FM Src2 Freeze Off, FM
Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip
Record, FM Src2 Clip Stop, FM1 to FM8 Clip
Cueup, FM1 to FM8 Clip Play, FM1 to FM8 Clip
Stop, Shotbox ? Recall, Macro Take, Prefs Button ?,
Macro ? Recall, No Action
•
When the trigger type is “Rising Edge” or “Falling
Edge”
Aux ? O'ride Src ??
Select a source from the following.
Primary inputs: 1 to 48 (33 to 48 are disabled on the
MVS-6520/3000A/3000)
Format converter dedicated inputs: 49 to 56