103BCommunication
10.2 PROFINET
S7-1200 Programmable controller
System Manual, 11/2011, A5E02486680-05
423
ERROR
STATUS
Description
1
C0808900
The parameters of the CONF_DATA data block field_type_id are invalid or have been
used several times.
1
C0808A00
LEN length of the IP configuration parameters or subfield_cnt errors
1
C0808B00
The IP configuration ID parameter is invalid or unsupported.
1
C0808C00
The Sub-block of the IP configuration is incorrectly placed (Sub-block wrong, wrong order,
or used multiple times).
1
C0808D00
The length of a statement LEN Sub-blocks is invalid.
1
C0808E00
The value of the parameter in Sub-blocks mode is invalid.
1
C0808F00
Sub-block conflict between the IP configuration and a previous Sub-block.
1
C0809000
The parameters of the subfield are write-protected (for example: parameters are specified
by configuration, or PNIO mode is enabled).
1
C0809100
Reserved
1
C0809400
A parameter in the Sub-block IP configuration has not been defined or may not be used.
1
C0809500
There is an inconsistency between a parameter of the Sub-block IP configuration and
other parameters.
1
C080C200
Instruction cannot be executed. This error can occur if, for example, communication with
the interface has been lost.
1
C080C300
There are not enough resources. This error can occur if, for example, the instruction is
called multiple times with different parameters
1
C080C400
Communication failure. The error can occur temporarily and will require a repeat of the
user program.
1
C080D200
Execution of the instruction is not supported by the PROFINET interface.
CONF_DATA Data block
The following diagram shows how the configuration data to be transferred is stored in the
configuration DB.