553BTechnical specifications
A.10 Communication interfaces
S7-1200 Programmable controller
System Manual, 11/2011, A5E02486680-05
743
A.10
Communication interfaces
A.10.1
PROFIBUS
Note
S7-1200 PROFIBUS CMs and the GPRS CP are not approved for Maritime applications
The following modules do not have Maritime approval:
CM 1242-5 PROFIBUS Slave module
CM 1243-5 PROFIBUS Master module
CP 1242-7 GPRS module
Note
To use these modules, your CPU firmware must be V2.0 or higher.
A.10.1.1
CM 1242-5
Table A- 148 Technical specifications of the CM 1242-5
Technical specifications
Order number
6GK7 242-5DX30-0XE0
Interfaces
Connection to PROFIBUS
9-pin D-sub female connector
Maximum current consumption on the PROFIBUS interface
when network components are connected (for example
optical network components)
15 mA at 5 V (only for bus termination) *
)
Permitted ambient conditions
Ambient temperature
during storage
during transportation
during operation with a vertical installation (DIN rail
horizontal)
during operation with a horizontal installation (DIN rail
vertical)
-40 °C to 70 °C
-40 °C to 70 °C
0 °C to 55 °C
0 °C to 45 °C
Relative humidity at 25 °C during operation, without
condensation, maximum
95 %
Degree of protection
IP20
Power supply, current consumption and power loss