Page 84
HydroRanger 200 – INSTRUCTION MANUAL
7ML19985FC03
mmmm
m
Te
st
ing the Confi
g
ur
at
ion
3.
Press the ARROW
or
to adjust the simulated rate of rise or fall, based on the
chart on page 84. The maximum rate is 4% of Span / second.
The effect of the ARROW key is determined by the state (rate of rise or fall) immediately
before the key is pressed.
When the level rises to 100% or falls to 0%, it reverses direction at the same rate.
Checking Volume Characterization [6 relay model]
To confirm universal volume calculations (P050 = 9, 10) are correct:
1.
Go to P920.
2.
Key in a level associated with a known volume.
3.
Press ENTER
.
4.
Check the returned volume against the manufacturer’s chart.
5.
Change parameters P054 and P055, as required.
6.
Repeat steps 2 to 5 until the volume curve is verified.
Checking OCM Flow Characterization [6 relay
model]
To confirm universal flow calculations (P600 = 4, 5) are accurate:
1.
Go to P925.
2.
Enter a level with a known flow.
3.
Press ENTER
.
Action
State (prior to pressing key)
Effect
Press
Stop
Rise at 1% of Span / second
Rise at 1% of Span / second
Rise at 4% of Span / second (max.)
Rise at 4% of Span / second (max.)
No effect
Fall at 1% of Span / second
Stop
Fall at 4% of Span / second
Fall at 1% of Span / second
Press
Stop
Fall at 1% of Span / second
Rise at 1% of Span / second
Stop
Rise at 4% of Span / second (max.)
Rise at 1% of Span / second
Fall at 1% of Span / second
Fall at 4% of Span / second (max.)
Fall at 4% of Span / second (max.)
No effect
Содержание HydroRanger 200
Страница 1: ...Instruction Manual July 2009 200 hydroranger ...
Страница 232: ...Page 222 HydroRanger 200 INSTRUCTION MANUAL 7ML19985FC03 mmmmm Parameters Notes ...
Страница 264: ...Page 254 HydroRanger 200 INSTRUCTION MANUAL 7ML19985FC03 mmmmm Appendix H Software Rev Notes ...
Страница 278: ...Notes ...
Страница 279: ......