Page 160
HydroRanger 200 – INSTRUCTION MANUAL
7ML19985FC03
mmm
mm
Pa
ra
m
e
te
rs
P330 Profile Record
Records profiles for later viewing.
In addition to being a profile records library, this provides two functions:
•
manually records and saves echo profiles
•
displays an echo profile, recorded manually or automatically
To select a record address
1.
Enter PROGRAM mode and press DISPLAY
twice to highlight the index field.
The field shows two underscores
_ _
.
2.
Type the index number. The profile record information is shown.
3.
Use ARROWS
to scroll through the records.
To manually record a profile
Press TRANSDUCER
to fire the transducer and record the echo profile into the
internal buffer for display.
HydroRanger 200 Features (All Models)
To save a manual record
Press ENTER
to copy the echo profile record in the buffer and save it in the selected
address in the record library. The parameter value field displays the new record
information.
Primary Index
Echo profile
Values
Code
Description
----
no record
A1
automatically recorded profile from Transducer One
A2
automatically recorded profile from Transducer Two
U1
manually recorded profile from Transducer One
U2
manually recorded profile from Transducer Two