ADC AND TOUCH SCREEN INTERFACE SPECIAL REGISTERS
ADC CONTROL (ADCCON) REGISTER
Register Address
R/W
Description
Reset
Value
ADCCON 0x58000000
R/W
ADC
control register
0x3FC4
ADCCON Bit
Description
Initial
State
ECFLG
[15]
End of conversion flag (read only).
0 = A/D conversion in process
1 = End of A/D conversion
0
PRSCEN
[14]
A/D converter prescaler enable.
0 = Disable
1 = Enable
0
PRSCVL
[13:6] A/D converter prescaler value.
Data value: 5 ~ 255
Note that division factor is (N+1) when the prescaler value is N.
Note:
ADC frequency should be set less than PCLK by 5 times.
(Ex. PCLK = 10MHz, ADC Frequency < 2MHz)
0xFF
Reserved [5:4]
Reserved
0
RESSEL
[3]
A/D converter resolution selection
0 = 10-bit resolution
1 = 12-bit resolution
0
STDBM
[2]
Standby mode select.
0 = Normal operation mode
1 = Standby mode
1
READ_ START
[1]
A/D conversion starts by read.
0 = Disable start by read operation
1 = Enable start by read operation
0
ENABLE_
START
[0]
A/D conversion starts by setting this bit.
If READ_START is enabled, this value is not valid.
0 = No operation
1 = A/D conversion starts and this bit is cleared after the start-up.
0