Video Main Control 0 Register
Register Address
R/W
Description
Reset
Value
VIDCON0 0x4C800000
R/W
Video
control 1 register
0x0000_0000
VIDCON0 Bit
Description
Initial
State
Reserved [31:24]
Reserved
0x00
VIDOUT
[23:22] It determines the output format of LCD Controller
00: RGB I/F
01: Reserved
10: i80-System I/F for Main LDI
11: i80-System I/F for Sub LDI
0
L1_DATA16 [21:19]
Select
the
mode of output data format of i80-System I/F (Sub LDI.)
(Only when, VIDOUT == 2’b11)
000 = 16-bit mode (16 bpp)
001 = 16 + 2 bit mode (18 bpp)
010 = 9 + 9 bit mode (18 bpp)
011 = 16 + 8 bit mode (24 bpp)
100 = 18-bit mode (18bpp)
000
L0_DATA16 [18:16]
Select
the
mode of output data format of i80-System I/F (Main LDI.)
(Only when, VIDOUT == 2’b10)
000 = 16 bit mode (16 bpp)
001 = 16 + 2 bit mode (18 bpp)
010 = 9 + 9 bit mode (18 bpp)
011 = 16 + 8 bit mode (24 bpp)
100 = 18 bit mode (18bpp)
000
Reserved [15]
Reserved
0
PNRMODE
[14:13] Select the display mode. (Where, VIDOUT == 2’b00)
00 = RGB Parallel format (RGB)
01 = RGB Parallel format (BGR)
10 = Serial Format (R->G->B)
11 = Serial Format (B->G->R)
Select the display mode. (Where, VIDOUT == 2’b1x)
00 = RGB Parallel format (RGB)
00