Remote control commands
R&S
®
NRX
282
User Manual 1178.5566.02 ─ 09
CALCulate<Measurement>:TRACe:MEASurement:DEFine:DURation:REFerence
<value>
Effective for pulse analysis measurements.
Sets the pulse width, pulse start time and pulse stop time.
Suffix:
<Measurement>
.
1 to 8
Measurement
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
50.0
Default unit: pct
Manual operation:
See
CALCulate<Measurement>:TRACe:MEASurement:DEFine:TRANsition:
HREFerence
<value>
Effective for pulse analysis measurements.
Defines the end of the rising edge and the start of the falling edge of the pulse. Used
for the measurement of the rise or fall time.
Suffix:
<Measurement>
.
1 to 8
Measurement
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
90.0
Default unit: pct
Manual operation:
See
CALCulate<Measurement>:TRACe:MEASurement:DEFine:TRANsition:
LREFerence
<value>
Effective for pulse analysis measurements.
Defines the start of the rising edge and the end of the falling edge of the pulse. Used
for the measurement of the rise or fall time.
Suffix:
<Measurement>
.
1 to 8
Measurement
Parameters:
<value>
Range:
0.0 to 100.0
*RST:
10.0
Default unit: pct
Manual operation:
See
Measurement settings and results