System settings
R&S
®
NRX
150
User Manual 1178.5566.02 ─ 09
OUTPut:RECorder<output>:LIMit:UPPer:RATio:RLOSs
OUTPut:RECorder<output>:LIMit:UPPer:RATio:SWR
OUTPut:RECorder<output>:LIMit:UPPer:RATio[:VALue]
OUTPut:RECorder<output>:LIMit:UPPer[:VALue]
Measurement for Limit Output ← I/O 1, I/O 2 tabs
Available if
is set to:
●
"Limit Violation"
●
"Forw Limit Violation"
●
"Refl Limit Violation"
Sets the measurement that is monitored.
Remote command:
[SENSe<Sensor>:]POWer:REFLection:RANGe:LOWer
[SENSe<Sensor>:]POWer[:POWer]:RANGe:LOWer
[SENSe<Sensor>:]POWer:REFLection:RANGe[:UPPer]
[SENSe<Sensor>:]POWer[:POWer]:RANGe[:UPPer]
OUTPut:LIMit:FEED:INDex
Fail Voltage ← I/O 1, I/O 2 tabs
Available if
is set to:
●
"Limit Violation"
●
"Forw Limit Violation"
●
"Refl Limit Violation"
Sets the fail voltage that is output if a measured value causes a limit violation.
"Low"
0
V
"High"
3.3
V
Remote command:
[SENSe<Sensor>:]POWer:REFLection:RANGe:AUTO
[SENSe<Sensor>:]POWer[:POWer]:RANGe:LIMit:DETect
OUTPut:LIMit:FAIL
Trigger Source for Trigger Output ← I/O 1, I/O 2 tabs
Available if
is set to "Trigger Out".
Sets the trigger source.
Remote command:
Impedance for Trigger Input ← I/O 1, I/O 2 tabs
Available if
is set to "Trigger In".
Sets the termination resistance of the external trigger signal that is supplied at the
Trig
In
/
Out
2 connector. Choose a setting that fits the impedance of the trigger source
to minimize reflections on the trigger signals.
Remote command:
INPut<undef>:TRIGger:IMPedance