SMIQ
Digital Standard DECT
1125.5555.03
2.331
E-9
(SELECT SLOT)
SLOT LEVEL
Selection of the level for the selected slot.
OFF
Maximum attenuation
IEEE bus
:SOUR:DECT:SLOT2:LEV OFF
FULL
The level corresponds to the value indicated on
the SMIQ LEVEL display.
IEEE bus
:SOUR:DECT:SLOT2:LEV FULL
ATTEN
The level is attenuated by the value set under
SLOT ATTENUATION.
IEEE bus
:SOUR:DECT:SLOT2:LEV ATT
Note:
If the cursor is placed onto a slot in the diagram,
the SLOT LEVEL may be modified by pressing
one of the unit keys (toggle function).
SET DEFAULT
Resets the subsequent parameters to factory-set default
values.
IEC/IEEE-bus command
SOUR:DECT:SLOT8:PRES
SLOT TIMING
SHIFT
Input value for the number of bits used for simulating a faulty
slot timing. The active slot is shifted in time by the selected
number of bits. A positive input value delays the slot, a
negative value advances the slot in time.
IEEE bus command
:SOUR:DECT:SLOT2:STSH 1
CW DURING
RAMP UP
Switches the modulation during the rise of the power ramp
on or off.
ON
Before the preamble starts, the modulation is
switched off so that only the unmodulated
carrier is generated.
OFF
Before the preamble starts, the modulation is
switched on and the data bits in the ramp field
are modulated.
IEEE bus command
:SOUR:DECT:SLOT2:RAMP:CW ON
RAMP
Input value for the 12-bit data field RAMP in binary format.
This data field is not defined in the DECT standard. It is used
to define the data contents during the rise of the power ramp.
A series of data representing the natural extension of the
preamble bits in forward direction is set by default.
IEEE
:SOUR:DECT:SLOT2:RAMP:DATA #B111111111111
NORMAL
PREAMBLE
Input value for the NORMAL PREAMBLE in binary format.
According to the DECT standard, the default setting for this
16-bit data field is different for uplink and downlink slots. This
data field is not available for slot type ALL_DATA.
IEEE
:SOUR:DECT:SLOT2:PRE:DATA #B1010...