![Rohde & Schwarz 1125.5555.02 Скачать руководство пользователя страница 321](http://html.mh-extra.com/html/rohde-and-schwarz/1125-5555-02/1125-5555-02_operating-manual_1477925321.webp)
Enhanced Functions For Digital Standard 3GPP W-CDMA (FDD)
SMIQ
1125.5555.03
2.252
E-9
TPC
Selects the data source for the TPC fields of the timeslots of the
corresponding enhanced channel.
In a submenu the data sources ALL0, ALL1 and a 24-bit PATTERN as well as
any data lists DLISTxx can be selected.
Only one bit is read out from the data source per TPC field. This bit is then
multiplied in the whole TPC field.
IEC/IEEE-bus
:SOUR:W3GP:BST:ENH:CHAN1:TPC ONE
IEC/IEEE-bus
:SOUR:W3GP:BST:ENH:CHAN1:TPC:PATT #H3F, 8
MULTI CODE
Switch with which the multicode channel trunking of the corresponding
downlink enhanced channel can be activated or deactivated with other
dedicated channels.
All dedicated channels of a base station whose multicode switch is set to ON
are trunked to form one virtual channel – irrespective of whether they are
declared as enhanced dedicated channels or as normal dedicated channels.
IEC/IEEE-bus command
:SOUR:W3GP:BST:ENH:CHAN1:MCOD OFF
SELECT DATA LIST...
CURRENT: DLIST01
Selects an available data list or generation of a new data list (in the submenu).
The currently selected data list is displayed on the right.
IEC/IEEE-bus command
:SOUR:W3GP:BST:ENH:DSEL 'ABC'
COPY CURRENT
DATA LIST TO...
Copies the contents of the current data list into an existing or new data list.
IEC/IEEE-bus command
:SOUR:DM:DLIS:COPY 'ABC'
DELETE DATA LIST...
Deletes an existing data list.
IEC/IEEE-bus command
:SOUR:DM:DLIS:DEL 'ABC'
EDIT DATA LIST...
Edits an existing data list.