![Rohde & Schwarz 1125.5555.02 Скачать руководство пользователя страница 248](http://html.mh-extra.com/html/rohde-and-schwarz/1125-5555-02/1125-5555-02_operating-manual_1477925248.webp)
SMIQ
Digital Standard 3GPP W-CDMA (FDD)
1125.5555.03
E-9
2.179
2.14.2.1 Menu
WCDMA/3GPP
The following figure shows the menu for generating a downlink signal (transmit signal of base station).
Fig. 2-104
DIGITAL STD - WCDMA/3GPP - Downlink
menu
For clarity, associated parameters are combined to subgroups by horizontal lines.
STATE
Switch-on/off of modulation - digital standard 3GPP W-CDMA. If vector
modulation, digital modulation or another digital standard are on, they are
automatically switched off.
STATE = ON starts the calculation of a chip sequence based on current
settings. The length of the chip sequence, and so the duration of the
calculation, is determined by the SEQUENCE LENGTH parameter.
IEC/IEEE-bus command
:SOUR:W3GP:STAT ON
Note
:
When a parameter is changed, STATE is automatically switched to OFF to ensure that the set
values and the output signal are consistent. After changing all the values, STATE can
manually be set to ON. This is possible via menu parameter STATE and with the MOD
ON/OFF key below the rollkey.
A progress bar is displayed while the chip sequence is calculated. The progress of the calculation can
also be read via the remote control interfaces.
IEC/IEEE-bus command
:SOUR:W3GP:CAL:PROG?