![Rohde & Schwarz 1125.5555.02 Скачать руководство пользователя страница 312](http://html.mh-extra.com/html/rohde-and-schwarz/1125-5555-02/1125-5555-02_operating-manual_1477925312.webp)
SMIQ
Enhanced Functions For Digital Standard 3GPP W-CDMA (FDD)
1125.5555.03
E-9
2.243
2.15.3.1.2 Channel
Coding
Many tests can be found in [1] and [3] all of which require channel-coded measurement channels, so-
called Reference Measurement Channels. Types 12.2 kbps, 64 kbps, 144 kbps and 384 kbps are
indicated for each link direction.
In addition, the SMIQ can simulate an AMR voice channel according to [5]. The detailed structure of
these channels is described in the following documents:
Table 2-27
References to measurement channels
CODING TYPE
Reference downlink
Reference uplink
MEASURE__12.2
[1], A.3.1
[3], A.2 and [4], A.2
MEASURE__64
[1], A.3.2
[3], A.3 and [4], A.3
MEASURE_144
[1], A.3.3
[3], A.4 and [4], A.4
MEASURE_384
[1], A.3.5
[3], A.5 and [4], A.5
AMR_CODER
[5], 4.1.1.3.1.2
[5], 4.1.2.2.1.2
To simplify the implementation of channel decoding in the test receiver the two interleaver stages in the
measurement channels can separately be switched on and off.
----------------------
Channel Coding
-----------------------------------------------------------------------------
CHANNEL CODING
STATE
Switch for activating or deactivating the channel coding of all enhanced
channels.
In the OFF state, the following menu parameters are not effective:
CODING TYPE,
INTERLEAVER 1,
INTERLEAVER 2,
CODING (enhanced channel specific).
IEC/IEEE-bus command
:SOUR:W3GP:BST:ENH:CCOD ON
CODING TYPE
Setting the channel coding type of all enhanced channels.
The 3GPP specification currently stipulates 4 predefined MEASUREMENT
channel coding types which differ in the input data bit rate to be processed
(12.2, 64, 144 and 384 KBPS). The additional AMR_CODER coding scheme
generates the coding of a speech channel.
For channel coding, the input data bits are taken from the data source
specified in menu parameter DATA. The bits with a higher data rate are
available at the output of channel coding. There are fixed assignments
between the measurement input data bit rate and the output symbol rate, i.e.
the menu parameters SYMBOL RATE DPCH (Downlink) or OVERALL
SYMBOL RATE are adapted automatically.
MEASURE_12.2
Measurement channel 12.2 kbps
MEASURE_64
Measurement channel 64 kbps
MEASURE_144
Measurement channel 144 kbps
MEASURE_384
Measurement channel 384 kbps
AMR_CODER
Channel coding for AMR Coder
IEC/IEEE-bus command
:SOUR:W3GP:BST:ENH:CCOD:TYP M12K
INTERLEAVER 1,2
Switch for separately activating or deactivating channel coding interleaver stages 1
and 2 of all enhanced channels. (The interleaver stages do not change the symbol
rate.)
IEC/IEEE-bus command
:SOUR:W3GP:BST:ENH:CCOD:INT1 ON