Digital Standard 3GPP W-CDMA (FDD)
SMIQ
1125.5555.03
E-9
2.194
Parameters that are valid for the current base station:
BS 1(2,3,4) STATE
ON
The BS is active. All other parameters are activated.
IEC/IEEE-bus command
:SOUR:W3GP:BST1:STAT ON
OFF
The BS is inactive. The other parameters are ignored.
IEC/IEEE-bus command
:SOUR:W3GP:BST2:STAT OFF
SCRAMBLING CODE
STATE
ON
The scrambling code is active.
IEC/IEEE-bus
:SOUR:W3GP:BST1:SCOD:STAT ON
OFF
The scrambling code is inactive (test mode).
IEC/IEEE-bus
:SOUR:W3GP:BST2:SCOD:STAT OFF
SCRAMBLING CODE
Code of base station. At the same time, the initial value for the scrambling code
generator. Permissible values are in the range 0 to 0x5FFF.
IEC/IEEE-bus command
:SOUR:W3GP:BST1:SCOD #H1
TFCI STATE
ON
TFCI field is used in the frame.
IEC/IEEE-bus command
:SOUR:W3GP:BST1:TFCI:STAT ON
OFF
TFCI field is not used in the frame.
IEC/IEEE-bus command
:SOUR:W3GP:BST2:TFCI:STAT OFF
TFCI (DPCH)
Setting the TFCI value in the range 0 to 1023. A combination of 30 bits is
selected by this value. This combination is distributed over 15 successive slots
in groups of two.
IEC/IEEE-bus command
:SOUR:W3GP:BST4:TFCI 21
2
ND
SEARCH CODE
GROUP
This parameter indexes the “Allocation of SSCs for secondary SCH“ table
described in the 3GPP standard, reference [2], Table 9. For each slot in the
frame, this table assigns a certain spreading code to the synchronization code
symbol. The parameter’s range is 0 to 63. This parameter can only be read.
The value is calculated from the SCRAMBLING CODE.
IEC/IEEE-bus command
:SOUR:W3GP:BST3:SSCG?
TPC PATTERN READ
OUT MODE
TPC bits are used for W-CDMA to inform the called station if the transmit
power is being increased or decreased. The contents of the TPC field can be
separately defined in this panel in the table below for the channels of the BS.
The parameter TPC Pattern Read Out Mode is used to define how this bit
pattern is to be used. The following modes are distinguished:
•
Continuous: A bit is taken for each slot from the up to 24-bit long bit
pattern for the Transmitter Power Control field of the slots and entered in
the bit stream several times (depending on the symbol rate). The specified
bit pattern is used cyclically.
•
All 0: A bit is taken for each slot from the up to 24-bit long bit
pattern for the Transmitter Power Control field of the slots and entered the
bit stream several times (depending on the symbol rate). The specified bit
pattern is used once, then the TPC sequence is continued with 0 bits.
•
All 1: A bit is taken for each slot from the max. 24-bit long bit
pattern for the Transmitter Power Control field of the slots and entered in
the bit stream several times (depending on the symbol rate. The specified
bit pattern is used once, then the TPC sequence is continued with 1 bits.