Publication 20D-UM006G-EN-P – July 2008
This information summarizes the changes to the PowerFlex 700S High
Performance AC Drive - Phase II Control User Manual, publication
20D-UM006, since the September 2005 release.
Updated the description for options 34 “UserGen Sel0” - 37 “UserGen Sel3” for Pars 825 - 830
Added a list of parameters corresponding to the value selected in Par 831 [Anlg Out1 Sel]
Updated the description for Par 1022 [Sel Switch Ctrl]
Added new fault code 79 “HiHP Bus Data”
Updated the Bus Overvoltage Trip levels
Added information on DPI device limitations
Update the “Drive, Fuse & Circuit Breaker Ratings” tables
Updated the DriveLogix - Motion Control Block Diagram
Updated wiring diagram for Rotary Encoder connections
Added new Appendix for SynchLink Specifications
Change
See Page...
Updated the Power Terminal Block Specification Descriptions
Updated the Terminal Block specifications for digital input leakage current
Updated the HIM Start Up Menu diagram
Updated the Min./Max. values for parameter 75 [Rev Speed Limit]
Updated the Min./Max. values for parameter 76 [Fwd Speed Limit]
Added values 9 and 10 to parameter 150 [Logic State Mach]
Added value 8 to parameter 165 [Tune Test Status]
Updated the trigger Source settings for parameter 236 [RegisLtch 0/1Cnfg]
Changed parameter 321 [Exception Event2] / bit 14 to a non-configurable alarm
Changed parameter 322 [Exception Event3] / bit 11, 12, 13, 21 and 28 to a non-configurable
alarms
Changed parameter 324 [Fault Status 2] / bit 14 to a non-configurable alarm
Changed parameter 325 [Fault Status 3] / bit 21 to Drive Homing” and bit 28 to “+/- 12v Pwr”
Changed parameter 327 [Alarm Status 2] / bit 14 to a non-configurable alarm
Changed parameter 328 [Alarm Status 3] / bit 21 to Drive Homing” and bit 28 to “+/- 12v Pwr”
Added values 45, 46 and 47 to parameter 347 [Drive OL TP Sel]
Added values 20 - 52 to parameter 357 [Curr Ref TP Sel]
Changed bit 3 to “FastFluxDsbl” for parameter 510 [FVC Mode Config]
Changed bit 3 to “FastFluxDsbl” for parameter 513 [V/Hz Mode Config]
Updated the default and Min./Max. values for parameter 532 [Maximum Frequency]
Change bit 18 to ”Vqs Reg Act” for parameter 555 [MC Status]
Added bit 9 “Watch Fb Arm” and bit 10 ”WatchFbPosit” to parameter 691 [Motn EventStatus]
Added bit 7 “Watch Fb Rev” to parameter 692 [Motn Event Ctrl]
Updated Parameter 554 [LED Status] to include a description
Updated the description for bit 7 “AbsoluteMode” of parameter 740 [Position Control]
Updated the description for bit 0 “Absolute” of parameter 1134 [PPMP Control]
Updated fault 33 “+/- 15volt Power” to new voltage band settings
Added new event 86 “Drive Homing”
Added new event 93 “+/- 12volt Power Alarm”
Updated the Specifications table for C-tick Agency Certification, drive sound levels, and encoder
voltage supply data.
Updated the Drive, Fuse & Circuit Breaker Ratings tables.
Updated wiring diagram for Rotary Encoder connections.
Added new Appendix for ATEX approved PowerFlex 700S Phase II Drives in Group II Category (2)
applications with ATEX approved motors.
Change
See Page...
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......