Programming and Parameters
3-33
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
228
MtrSpd Simulated
The motor speed output of the motor simulator. The motor simulator provides motor speed
information during setup and troubleshooting when actual motor control is not desired or
possible. To use the motor simulator, enter a value of 4 in
[Mtr Fdbk Sel Alt].
Units:
Default:
Min/Max:
Scale:
RPM
0.0000
-/+14112.0000
[Motor NP RPM] = 1.0pu
RO Real
229
MtrPosit Simulat
The motor position output of the motor simulator. The motor simulator provides motor position
information during setup and troubleshooting when actual motor control is not desired or
possible. To use the motor simulator, enter a value of 4 in
[Mtr Fdbk Sel Alt].
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
230 Encdr0
Position
Displays the position feedback (accumulator) from encoder 0. The value changes by a value
of four times (4x) the Pulses Per Revolution (PPR) rating of the encoder for each full
revolution of the encoder shaft. Used by the Velocity Position Loop (VPL) to close the position
loop if position control is selected.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
231
Encdr0 Spd Fdbk
Displays the speed feedback from encoder 0. Calculated from the change of
[Encdr0
Position] and
[Encoder0 PPR].
Units:
Default:
Min/Max:
Scale:
RPM
0.0000
-/+14112.0000
[Motor NP RPM] = 1.0pu
RO Real
232 Encoder0
PPR
Sets the pulse per revolution rating of the feedback device connected to the Encoder 0 input.
This parameter must be set to one of the values displayed in bold in Table 232A below.
Units:
Default:
Min/Max:
PPR
1024
10/20000
RW 16-bit
Integer
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Table 232A: PPR Rating Values
n =
2
n
=
x
mod 75
mod 125 mod 225 mod 375 mod 625 mod1125
0
1
75
125
225
375
625
1125
1
2
150
250
450
750
1250
2250
2
4
300
500
900
1500
2500
4500
3
8
600
1000
1800
3000
5000
9000
4
16
1200
2000
3600
6000
10000
18000
5
32
2400
4000
7200
12000
20000
--
6
64
--
--
--
--
--
--
7
128
--
--
--
--
--
--
8
256
--
--
--
--
--
--
9
512
--
--
--
--
--
--
10
1024
--
--
--
--
--
--
11
2048
--
--
--
--
--
--
12
4096
--
--
--
--
--
--
13
8192
--
--
--
--
--
--
14
16384
--
--
--
--
--
--
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......