A-8
Supplemental Information
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
Table A.C 400 Volt AC Input Frames 1 - 6 Drive Ratings
Table A.D 400 Volt AC Input Frames 9 - 13 Drive Ratings
Drive Catalog
Number
Fr
ame kW Rating
PWM
Freq.
Temp.
(3)
(3)
The temperature rating listed for frame size 1-4 drives is for NEMA open types only. The adhesive tape label
must be removed in order to operate at this temperature, otherwise the ambient operating temperature of these
drives is 40
°
C.
Input Ratings
Output Amps
ND
HD
kHz
°
C
Amps
kVA
Cont.
1 Min.
3 Sec.
20DC2P1
1
0.75
0.55
4
50
1.8
1.3
2.1
2.4
3.2
20DC3P5
1
1.5
1.1
4
50
3.2
2.2
3.5
4.5
6.0
20DC5P0
1
2.2
1.5
4
50
4.6
3.2
5.0
5.5
7.5
20DC8P7
1
4
3.0
4
50
7.9
5.5
8.7
9.9
13.2
20DC011
1
5.5
4
4
50
10.8
7.5
11.5
13
17.4
20DC015
1
7.5
5.5
4
50
14.4
10.0
15.4
17.2
23.1
20DC022
1
11
7.5
4
50
20.6
14.3
22
24.2
33
20DC030
2
15
11
4
50
28.4
19.7
30
33
45
20DC037
2
18.5
15
4
50
35.0
24.3
37
45
60
20DC043
3
22
18.5
4
50
40.7
28.2
43
56
74
20DC056
3
30
22
4
50
53
36.7
56
64
86
20DC072
3
37
30
4
45
68.9
47.8
72
84
112
20DC085
(1)
(1)
20DC085 current rating is limited to 45 degrees C ambient.
4
45
–
4
50
81.4
56.4
85
94
128
–
37
4
50
68.9
47.8
72
108
144
20DC105
5
55
–
4
50
(4)
(4)
UL Type 12/IP54 (flange mount) heatsink ambient temperature rating is 40
°
C/ambient of unprotected drive
portion (inside enclosure) is 55
°
C. The ambient temperature for the UL Type 12/IP54 standalone drives is 40
°
C.
100.5
69.6
105
116
158
–
45
4
50
(4)
81.4
56.4
85
128
170
20DC125
5
55
–
4
50
(4)
121.1
83.9
125
138
163
–
45
4
50
(4)
101
63.7
96
144
168
20DC140
5
75
–
4
50
(4)
135.6
94
140
154
210
–
55
4
50
(4)
121
69.6
105
158
210
20DC170
6
90
–
4
50
(4)
164.6
114
170
187
255
–
75
4
50
(4)
136
94
140
210
280
20DC205
(2)
(2)
20DC205 current rating is limited to 40 degrees C ambient.
6
110
–
4
40
(4)
198.5
138
205
220
289
–
90
4
40
(4)
164
114
170
255
313
20DC260
6
132
–
2
40
(4)
254.7
166
260
286
390
–
110
2
40
(4)
199
138
205
308
410
Drive Catalog
Number
Fr
ame kW Rating
PWM
Freq.
Temp.
Input
Ratings
Output Amps
Watts
Loss
ND
HD
kHz
°
C
Amps
Cont.
1 Min.
3 Sec.
Watts
20DC261
9
132
-
2
40
263
261
287
410
2700
-
110
2
40
207
205
308
410
2700
20DC300
9
160
-
2
40
302
300
330
450
3100
-
132
2
40
247
245
368
490
3100
20DC385
10
200
-
2
40
388
385
424
600
4320
-
160
2
40
302
300
450
600
4320
20DC460
10
250
-
2
40
463
460
506
770
5335
-
200
2
40
388
385
578
770
5335
20DC500
10
250
-
2
40
504
500
550
750
5921
-
250
2
40
423
420
630
840
5921
20DC590
11
315
-
2
40
594
590
649
956
6620
-
250
2
40
524
520
780
956
6620
20DC650
11
355
-
2
40
655
650
715
1062
7538
-
315
2
40
594
590
885
1062
7538
20DC730
11
400
-
2
40
735
730
803
1095
8312
-
355
2
40
655
650
975
1170
8312
20DC820
12
450
-
2
40
826
820
902
1230
9201
-
400
2
40
735
730
1095
1314
9201
20DC920
12
500
-
2
40
927
920
1012
1380
10670
-
450
2
40
826
820
1230
1476
10670
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......