BasicIndx Step
Sets the amount added to or subtracted from
[BasicIndx Output] on a rising edge of
[Position Control], bit 12 “BscIndx Step”. Note that this value can be positive or
negative.
Default:
Min/Max:
0
-/+2147483648
✓
RW 32-bit
Integer
798
BasicIndx Preset
Sets the value to be moved into
[Position Control],
bit 11 “BscIndx Enbl” and bit 14 “BscIndx Prst” are both on.
Default:
Min/Max:
0
-/+2147483648
✓
RW 32-bit
Integer
799
BasicIndx Output
Displays the output of the Position Index function.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
800
Anlg In1 Data
Displays the scaled final value for Analog Input 1.
Default:
Min/Max:
0.0000
-/+2200000000.0000
RO Real
801
Anlg In1 Value
Displays the actual input value at Analog Input 1. Analog Input 1 may be configured for
voltage or current input signal. For proper selection of the input signal, the DIP switch S-5 and
[Analog I/O Units] must be set to match. Par 801 [Anlg In1 Value] is multiplied by the
value in
[Anlg In1 Scale] to produce the input to the lead lag filter function.
Units:
Default:
Min/Max:
V/mA
0.0000
-/+20.0000
RO Real
802
Anlg In1 Scale
Scales the range of Analog Input 1 to the range of
[Anlg In1 Data]. Enter the units you
want per volt or mA. For example: If Par 801 [Anlg In1 Value] = 0 - 10V and you enter “6” in
this parameter, Par 800 [Anlg In1 Data] will equal 0 - 60V.
Par 801 * Par 802 = Par 800.
Units:
Default:
Min/Max:
/V or /mA
0.1000
-/+2200000000.0000
✓
RW Real
803
Anlg In1 Offset
Applies an offset to Analog Input 1. Use the offset to correct for zero signal errors or to create
an offset to the actual input. The output of the A/D converter is summed with this parameter to
produce
[Anlg In1 Value].
Units:
Default:
Min/Max:
V/mA
0.0000
-/+20.0000
✓
RW Real
804
AI 1 Filt Gain
Provides the Lead term for the Analog Input 1 filter.
Default:
Min/Max:
1.0000
-/+5.0000
✓
RW Real
805
Anlg In1 Filt BW
Provides the Lag term for the Analog Input 1 filter.
Units:
Default:
Min/Max:
R/S
0.0000
0.0000/3760.0000l
✓
RW Real
806
Anlg In2 Data
Displays the scaled final value for Analog Input 2.
Default:
Min/Max:
0.0000
-/+2200000000.0000
RO Real
807
Anlg In2 Value
Displays the actual input value at Analog Input 2. Analog Input 2 may be configured for
voltage or current input signal. For proper selection of the input signal, the DIP switch S-5 and
[Analog I/O Units] must be set to match. Par 807 [Anlg In2 Value] is multiplied by
[Anlg In2 Scale] produce the input to the lead lag filter function.
Units:
Default:
Min/Max:
V/mA
0.0000
-/+20.0000
RO Real
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Type of Input: Configurable, Voltage or Current
Polarity:
Bi-Polar
Resolution:
14 bit (-8191 to +8191)
DIP Switch
Analog I/O Units
AI 1 Voltage
S5-2 = Open
Par 821 Bit 0 = 0 (False)
AI 1 Current
S5-2 = Closed
Par 821 Bit 0 = 1 (True)
Light
Heavy
[Al 1 Filt Gain]
0.25
0.1
Par 805 [Anlg In1 Filt BW]
50
10
Type of Input:
Configurable, Voltage or Current
Polarity:
Bi-Polar
Resolution:
14 bit (-8191 to +8191)
DIP Switch
Analog I/O Units
AI 2 Voltage
S5-1 = Open
Par 821 Bit 1 = 0 (False)
AI 2 Current
S5-1 = Closed
Par 821 Bit 1 = 1 (True)
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......