Programming and Parameters
3-107
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
1001
UserFunct Actual
This parameter displays the actual status of the user functions. If a bit is set, then the corresponding function is active. When Par 1001 [UserFunct Actual] does not
match
[UserFunct Enable] it is an indication that the function could not activate because of an error. Typically, the limitation is caused by processor
overloading. Adjust
[FW TaskTime Sel] to a slower task cycle (more time).
1002
to
1011
UserData DInt 01
to
UserData DInt 10
These are general purpose parameters available for storage of 32-bit enumerated data or DInt
data by the user. These parameters will be retained through power cycles.
Default:
Min/Max:
0
-/+2147483648
✓
RW 32-bit
Integer
1012
to
1021
User Data Real 01
to
UserData Real 10
These are general purpose parameters available for storage of Real data by the user. These
parameters will be retained through power cycles.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
1022
Sel Switch Ctrl
This is the control parameter for the switches used by the Selector Switch user functions. 16 Input Selector Switches (Pars 1029 - 1044) are controlled by bits 1-4.
•
Bit 0 “SSW DataPass” Updates the output. If bit 0 is low, the output is NOT updated with the selected input.
•
Bits 1 “Sel Swtch 00” - 4 “Sel Swtch 03” Binary coded selection of the 16 inputs to the switch. Bit 1 is the Least Significant Bit. If these bits are all low (set to “0”),
Par 1029 is selected. If these bits are all high (set to “1”) Par 1044 is selected. (Refer to Pars
-
.) The values in these bits can be controlled by the
digital inputs. (Refer to Pars
and to the “Selector Switches” section of the PowerFlex 700S Drives with Phase II Control - Reference Manual, publication
PFLEX-RM003..., for more information.)
•
Bit 5 “SW Real 1 On” activates the Real switch. (Refer to Pars
.)
•
Bit 6 “SW DInt 1 On” activates the DInt switch. (Refer to Pars
1023
Swtch Real 1 NC
This is the Normally Closed input to the Real switch. When
[Sel Switch Ctrl], bit 5
“SW Real 1 On” is low, this input is updated to
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
1024
Swtch Real 1 NO
This is the Normally Open input to the Real switch. When
[Sel Switch Ctrl], bit 5 “SW
Real 1 On” is high, this input is updated to
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
1025
Swtch Real 1 Out
This is the result of the Real switch. The output is loaded with the selected input based on
[Sel Switch Ctrl], bit 5 “SW Real 1 On”. If this parameter does not update, check the
[UserFunct Enable], bit 1 “User Params”.
Default:
Min/Max:
0.0000
-/+2200000000.0000
RO Real
1026
Swtch DInt 1 NC
This is the Normally Closed input to the DInt switch. When
[Sel Switch Ctrl], bit 6
“SW DInt 1 On” is low, this input is updated to
[Swtch DInt 1 Output].
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW 32-bit
Integer
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Options
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
MO
P
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
MulD
iv
Ma
th
Logic Fun
ct
s
Con
ver
ts
Sel Switche
s
User P
ar
ams
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
SW
D
Int
1 O
n
SW R
eal 1
On
Sel Swtc
h 03
Sel Swtc
h 02
Sel Swtc
h 01
Sel Swtc
h 00
SSW DataP
as
s
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......