Table A.A 208 Volt AC Input Frames 1-6 Drive Ratings
Table A.B 240 Volt AC Input Frames 1 - 6 Drive Ratings
Drive
Catalog
Number
Frame
kW Rating
PWM
Freq.
Temp.
(1)
(1)
The temperature rating listed for frame size 1-4 drives is for NEMA open types only. The adhesive tape label
must be removed in order to operate at this temperature, otherwise the ambient operating temperature of these
drives is 40
°
C.
Input Ratings
Output Amps
ND
HD
kHz
°
C
Amps
kVA
Cont.
1 Min.
3 Sec.
20DB4P2
1
0.75
0.55
4
50
3.7
1.3
4.8
5.6
7.0
20DB6P8
1
1.5
1.1
4
50
6.8
2.4
7.8
10.4
13.8
20DB9P6
1
2.2
1.5
4
50
9.5
3.4
11
12.1
17
20DB015
1
4.0
3.0
4
50
15.7
5.7
17.5
19.3
26.3
20DB022
1
5.5
4.0
4
50
23.0
8.3
25.3
27.8
38
20DB028
2
7.5
5.5
4
50
29.6
10.7
32.2
38
50.6
20DB042
3
11
7.5
4
50
44.5
16.0
48.3
53.1
72.5
20DB052
3
15
11
4
50
51.5
18.6
56
64
86
20DB070
4
18.5
15
4
50
72
25.9
78.2
93.1
124.2
20DB080
4
22
18.5
4
50
84.7
30.5
92
117.3
156.4
20DB104
5
30
–
4
50
113
40.7
120
132
175
–
22
4
50
84.7
30.5
92
138
175
20DB130
5
37
–
4
50
141
44.1
130
143
175
–
30
4
50
113
35.3
104
156
175
20DB154
6
45
–
4
50
167
60.1
177
195
266
–
37
4
50
141
50.9
150
225
300
20DB192
6
55
–
4
50
208
75.0
221
243
308
–
45
4
50
167
60.1
177
266
308
20DB260
6
66
–
2
45
255
96.7
260
286
390
–
55
2
50
199
71.7
205
305
410
Drive
Catalog
Number
Fr
ame HP Rating
PWM
Freq.
Temp.
(1)
(1)
The temperature rating listed for frame size 1-4 drives is for NEMA open types only. The adhesive tape label
must be removed in order to operate at this temperature, otherwise the ambient operating temperature of these
drives is 40
°
C.
Input Ratings
Output Amps
ND
HD
kHz
°
C
Amps
kVA
Cont.
1 Min.
3 Sec.
20DB4P2
1
1
0.75
4
50
3.3
1.4
4.2
4.8
6.4
20DB6P8
1
2
1.5
4
50
5.9
2.4
6.8
9
12
20DB9P6
1
3
2
4
50
8.3
3.4
9.6
10.6
14.4
20DB015
1
5
3
4
50
13.7
5.7
15.3
16.8
23
20DB022
1
7.5
5
4
50
19.9
8.3
22
24.2
33
20DB028
2
10
7.5
4
50
25.7
10.7
28
33
44
20DB042
3
15
10
4
50
38.5
16.0
42
46.2
63
20DB052
3
20
15
4
50
47.7
19.8
52
63
80
20DB070
4
25
20
4
50
64.2
26.7
70
78
105
20DB080
4
30
25
4
50
73.2
30.5
80
105
140
20DB104
5
40
–
4
50
98
40.6
104
115
175
–
30
4
50
73
30.5
80
120
160
20DB130
5
50
–
4
50
122
50.7
130
143
175
–
40
4
50
98
40.6
104
156
175
20DB154
6
60
–
4
50
145
60.1
154
169
231
–
50
4
50
122
50.7
130
195
260
20DB192
6
75
–
4
50
180
74.9
192
211
288
–
60
4
50
145
60.1
154
231
308
20DB260
6
100
–
2
45
233
96.8
260
286
390
–
75
2
50
169
74.9
205
305
410
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......