3-58
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
387
Lgx Timeout Cnfg
Enter a value to configure the drive's response to a “Controller-to-Drive” connection timeout,
as detected by the drive.
•
0 - Ignore configures the drive to continue running, as normal, when this event occurs.
•
1 - Alarm configures the drive to continue running and set the appropriate alarm bit when
this event occurs.
•
2 - FltCoastStop configures the drive to perform a coast stop and set the appropriate fault
bit, in response to this event.
•
3 - Flt RampStop configures the drive to perform a ramp stop and set the appropriate fault
bit, in response to this event.
•
4 - FltCurLimStp configures the drive to perform a current-limit stop and set the appropriate
fault bit, in response to this event.
Default
Options:
2 =
0 =
1 =
2 =
3 =
4 =
“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”
“Flt RampStop”
“FltCurLimStp”
388
Lgx Closed Cnfg
Enter a value to configure the drive's response to the controller closing the
“Controller-to-Drive” connection.
•
0 - Ignore configures the drive to continue running, as normal, when this event occurs.
•
1 - Alarm configures the drive to continue running and set the appropriate alarm bit when
this event occurs.
•
2 - FltCoastStop configures the drive to perform a coast stop and set the appropriate fault
bit, in response to this event.
•
3 - Flt RampStop configures the drive to perform a ramp stop and set the appropriate fault
bit, in response to this event.
•
4 - FltCurLimStp configures the drive to perform a current-limit stop and set the appropriate
fault bit, in response to this event.
Default
Options:
2 =
0 =
1 =
2 =
3 =
4 =
“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”
“Flt RampStop”
“FltCurLimStp”
389 Lgx
LinkChngCnfg
Enter a value to configure the drive's response to “Controller-to-Drive” default links being
removed. A default link is a link automatically set up when a communication format is
selected for the Controller to Drive connection.
•
0 - Ignore configures the drive to continue running, as normal, when this event occurs.
•
1 - Alarm configures the drive to continue running and set the appropriate alarm bit when
this event occurs.
•
2 - FltCoastStop configures the drive to perform a coast stop and set the appropriate fault
bit, in response to this event.
•
3 - Flt RampStop configures the drive to perform a ramp stop and set the appropriate fault
bit, in response to this event.
•
4 - FltCurLimStp configures the drive to perform a current-limit stop and set the appropriate
fault bit, in response to this event.
Default
Options:
2 =
0 =
1 =
2 =
3 =
4 =
“FltCoastStop”
“Ignore”
“Alarm”
“FltCoastStop”
“Flt RampStop”
“FltCurLimStp”
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
!
ATTENTION: Risk of injury or equipment damage exists.
[Lgx Timeout Cnfg] lets you determine
the action of the drive if communications are disrupted. By default this parameter causes the drive fault and
coast to a stop. You can set this parameter so that the drive continues to run. Precautions should be taken to
ensure that the setting of this parameter does not create hazards of injury or equipment damage.
!
ATTENTION: Risk of injury or equipment damage exists.
[Lgx Closed Cnfg] lets you determine the
action of the drive if communications are disrupted. By default this parameter causes the drive fault and coast
to a stop. You can set this parameter so that the drive continues to run. Precautions should be taken to ensure
that the setting of this parameter does not create hazards of injury or equipment damage.
!
ATTENTION: Risk of injury or equipment damage exists.
[Lgx LinkChngCnfg] lets you determine
the action of the drive if communications are disrupted. By default this parameter causes the drive fault and
coast to a stop. You can set this parameter so that the drive continues to run. Precautions should be taken to
ensure that the setting of this parameter does not create hazards of injury or equipment damage.
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......