3-112
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
1108
DelTmr1 TrigData
Link a word to this parameter that will control a user-defined on or off delay timer. The bit
within the selected word that will control the delay timer is set by
[DelTmr1 Trig Bit].
The user-defined on/off delay timer is enabled by setting bit 6 “Delay Timer” of
[UserFunct Enable].
Note: This parameter was added for firmware version 3.01.
Default:
Min/Max:
0
32 bits of data
✓
RW 32-bit
Boolean
1109
DelTmr1 Trig Bit
Selects the bit, from the word linked to
[DelTmr1 TrigData], that will change the
status of the user-defined delay timer to on or off. When Par 1109 [DelTmr1 Trig Bit] is a
positive number, the delay timer is an “on” timer. When Par 1109 is a negative number, the
delay timer is an “off” timer.
Note: This parameter was added for firmware version 3.01.
Default:
Min/Max:
0
-/+32
RW 16-bit
Integer
1110
DelayTimer1PrSet
The time that the value in
[DelayTimer1Accum] must reach before bit 2 “Timer
Done” in
[DelayTimer1Stats] is set.
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
Sec.
0
0/600.00
✓
RW 16-bit
Integer
1111
DelayTimer1Accum
The amount of time that has elapsed since the timer was enabled (
[DelayTimer1Stats], bit 2 set).
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
Sec.
0
0/600.00
RO 16-bit
Integer
1112
DelayTimer1Stats
Displays the status of the user-defined on or off delay timer.
Bit 0 “Timer Enable” when this bit is set, the timer is enabled.
Bit 1 “Timer Timing” when this bit is set, the timer is running.
Bit 2 “Timer Done” when this bit is set, the timer is done.
Note: This parameter was added for firmware version 3.01.
1113
DelTmr2 TrigData
Link a word to this parameter that will control a user-defined on or off delay timer. The bit
within the selected word that will control the delay timer is set by
[DelTmr2 Trig Bit].
The user-defined on/off delay timer is enabled by setting bit 6 “Delay Timer” of
[UserFunct Enable].
Note: This parameter was added for firmware version 3.01.
Default:
Min/Max:
0
32 bits of data
✓
RW 32-bit
Boolean
1114
DelTmr2 Trig Bit
Selects the bit, from the word linked to
[DelTmr2 TrigData], that will change the
status of the user-defined delay timer to on or off. When Par 1114 [DelTmr2 Trig Bit] is a
positive number, the delay timer is an “on” timer. When Par 1114 is a negative number, the
delay timer is an “off” timer.
Note: This parameter was added for firmware version 3.01.
Default:
Min/Max:
0
-/+32
▲
RW 16-bit
Integer
1115
DelayTimer2PrSet
The time that the value in
[DelayTimer2Accum] must reach before bit 2 “Timer
Done” in
[DelayTimer2Stats] is set.
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
Sec.
0
0/60000
✓
RW 16-bit
Integer
1116
DelayTimer2Accum
The amount of time that has elapsed since the timer was enabled (
[DelayTimer2Stats], bit 1 set).
Note: This parameter was added for firmware version 3.01.
Units:
Default:
Min/Max:
Sec.
0
0/60000
RO 16-bit
Integer
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Delay
Timer 1
1108
1112
00
DelayTimer1 Data
1110
DelayTimer1PrSet
1111
DelayTimer1Stats
DelayTimer1Accum
1109
DelayTimer 1 Bit
00
00 Enabled
Timing
Done
Options
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Reser
ved
Timer Don
e
Timer Timing
Timer Ena
ble
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Delay
Timer 2
1113
1117
00
DelayTimer2 Data
1115
DelayTimer2PrSet
1116
DelayTimer2Stats
DelayTimer 2Accum
1114
DelayTimer2 Bit
00
00 Enabled
Timing
Done
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......