3-36
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
237 RegisLtch0/1
Ctrl
Configures the control for registration latch 0 and 1.
•
Set bit 0 “RL0 Arm Req” and bit 16 “RL1 Arm Req” to arm the registration logic for the next trigger event. The particular latch will be armed and ready to be
strobed on the next occurrence of the trigger input.
•
Set bit 1 “RL0 DisarmReq” and bit 17 “RL1 DisarmReq” to disarm the registration logic for next trigger event.
After the registration is captured, bit 0 “RL0 Arm Req” and bit 16 “RL1 Arm Req” automatically resets back to 0 after found. Bit 1 “RL0 DisarmReq” and bit 17 “RL1
DisarmReq” are only needed to disarm a registration latch that has not been found yet. Setting bits 1 and 17 will clear the bits 0 and 6. Setting bits 0 and 6 sets bits
0 “RL0 Armed” and bit 16 “RL1 Armed” and clears bits 1 “RL0 Found” and bit 17 “RL1 Found” of
[RegisLtch0/1Stat].
238
RegisLtch0/1Stat
Indicates the control status of registration latch 0 and 1.
•
Bit 0 “RL0 Armed” and bit 16 “RL1 Armed” indicates the registration latch is armed.
•
Bit 1 “RL0 Found” and bit 17 “RL1 Found” indicates the registration event has triggered the latch.
•
Rising edge of 'Arm request' will set the 'Armed' status bit.
•
Rising edge of 'Disarm request' will clear the 'Armed' status bit.
239 RegisLtch1
Value
Displays the registration data of port 1. Indicates the position reference counter value latched
by the external strobes. The strobe signal used to trigger the latch is configurable by
[RegisLtch 0/1Cnfg].
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
240 Encdr1
Position
Displays the position feedback (accumulator) from encoder 1. The value changes by a value
of four times (4x) the Pulses Per Revolution (PPR) rating of the encoder for each full
revolution of the encoder shaft. Used by the VPL to close the position loop if position control
is selected.
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
241
Encdr1 Spd Fdbk
Displays the speed feedback from encoder 1. Calculated from the change of
[Encdr1
Position] and
[Encoder1 PPR].
Units:
Default:
Min.Max:
Scale:
RPM
0
-/+14112.0000
[Motor NP RPM] = 1.0pu
RO Real
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Options
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
RL1 Disar
m
Req
RL1 Ar
m
Re
q
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
RL0 Disar
m
Req
RL0 Ar
m
Re
q
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
RL1 F
ound
RL1 Ar
med
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
Rese
rv
ed
RL0 F
ound
RL0 Ar
med
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......