3-32
Programming and Parameters
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
211
PeakDtct Status
Status of peak/level detectors. A peak detector sets its “Change” bit for one scan when it detects a peak. The” Change” bit is off when set or when the “Hold” bit is
on.
212
PkDtct1 In DInt
Integer input to the first peak/level detector.
Default:
Min/Max:
0
-/+2147483648
✓
RW 32-bit
Integer
213
PkDtct1 In Real
Floating point input to the first peak/level detector.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
214
PeakDtct1 Preset
The first detector (in set or hold modes) compares this value to its input for level detection.
When the detector trips (in set mode) it transfers the value of this parameter to its output.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
215
PeakDetect1 Out
Output from the first peak/level detector.
Default:
Min/Max:
0.0000
-/+2200000000.0000
RO Real
216
PkDtct2 In DInt
Integer input to second peak/level detector.
Default:
Min/Max:
0
-/+2147483648
✓
RW 32-bit
Integer
217
PkDtct2 In Real
Floating point input to second peak/level detector.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
218
PeakDtct2 Preset
The second detector (in set or hold modes) compares this value to its input for level detection.
When the detector trips (in set mode) it transfers the value of this parameter to its output.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓
RW Real
219
PeakDetect2 Out
Output from the second peak/level detector.
Default:
Min/Max:
0.00
0.00/1200.00
RO Real
221
Load Estimate
Displays the estimated load torque, which is the side effect of the speed observer and does
not include torque to accelerate or decelerate the motor if the inertia input is correct. The
value is provided for display purposes.
Units:
Default:
Min/Max:
P.U.
0.0
-/+8.0 pu
RO Real
222
Mtr Fdbk Sel Pri
Selects primary feedback device. The primary feedback device configuration must not be set
to fault on an event in order to allow operational feedback switch over to the alternate
feedback device set in
[Mtr Fdbk Sel Alt].
Notes:
[Motor Ctrl Mode] must be set to FOC for Sensorless feedback selection to be
active. Selection 5 is only available when compatible feedback option card is installed. This
parameter was changed to non-linkable for firmware version 3.01.
Default:
Options:
0 =
0 =
1 =
2 =
3 =
“Encoder 0”
“Encoder 0”
4 = “Motor Sim”
“Encoder 1”
5 = “FB Opt Port0”
“Sensorless”
“Reserved”
223
Mtr Fdbk Sel Alt
Selects alternate feedback device if the feedback device selected in
[Mtr Fdbk Sel
Pri] fails.
Notes:
[Motor Ctrl Mode] must be set to FOC for Sensorless feedback selection to be
active. Selection 5 is only available when compatible feedback option card is installed. This
parameter was changed to non-linkable for firmware version 3.01.
Default:
Options:
2 =
0 =
1 =
2 =
3 =
“Sensorless”
“Encoder 0”
4 = “Motor Sim”
“Encoder 1”
5 = “FB Opt Port0”
“Sensorless”
“Reserved”
224 TachSwitch
Level
Sets the detection level for the automatic tach loss switchover routine. A drop in feedback
speed at this percent of rated speed over 0.5 msec will cause a tach switch from primary to
alternate feedback device. This feature is enabled when bit 16 “Auto Tach Sw” in
[Control Options] is selected.
Setting this level lower will make the tach switch detection more sensitive and lower the
minimum speed at which a tach switch can occur. Setting this level higher will make the tach
switch less sensitive and raise the minimum speed for tach switch detection.
Note: This parameter was changed to non-linkable for firmware version 3.01.
Units:
Default:
Min/Max:
%
10.0000
5.0000/25.0000
RW Real
225
Virtual Edge/Rev
Set the EPR (Edges Per Revolution) scaling for calculating motor position. Used in the
calculation of the position feedback such as
[MtrPosit Stimulat].
Units:
Default:
Min/Max:
EPR
4096
10/16777216
RW 32-bit
Integer
226
Motor Speed Est
Displays the estimated motor speed, calculated when the selected feedback is sensorless or
when encoderless ridethrough is enabled.
Units:
Default:
Min/Max:
Scale:
RPM
0.0000
-/+14112.0000
[Motor NP RPM] = 1.0pu
RO Real
227
Motor Posit Est
[Motor Speed Est] scaled by the value in
[Virtual Edge/Rev].
Default:
Min/Max:
0
-/+2147483648
RO 32-bit
Integer
Options
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
P
eak 2 Chng
P
eak 1 Chng
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......