Programming and Parameters
3-49
PowerFlex 700S Phase II AC Drive User Manual -
Publication 20D-UM006G-EN-P – July 2008
325
Fault Status 3
Indicates the occurrence of exception events that have been configured as fault conditions. These events are from
[Exception Event3].
•
Bit 11 “HH HW Ver” is sed to indicate a High Horsepower hardware version fault.
•
Bit 12 “HH CurUnblnc” is used to indicate a High Horsepower output current unbalanced fault.
•
Bit 13 “HH VltUnblnc” is used to indicate a High Horsepower Bus voltage unbalanced fault.
•
Bit 29 “AnlgIn1 Loss” is used to indicate an Analog Input 1 loss fault.
•
Bit 30 “AnlgIn2 Loss” is used to indicate an Analog Input 2 loss fault.
•
Bit 31 “AnlgIn3 Loss” is used to indicate an Analog Input 3 loss fault.
Notes: Bits 16, 20 and 23 were added for firmware version 2.04. Bits 11, 12, 13, 29, 30 and 31 were added for firmware version 3.01. Changed bit 21 to “Drive
Homing” and bit 28 to “+/- 12v Pwr” for firmware version 3.03. Bit 14 “NonCnfgAlarm” was added for firmware version 3.04.
326
Alarm Status 1
Indicates the occurrence of exception events that have been configured as alarm conditions. These events are from
[Exception Event1].
327
Alarm Status 2
Indicates the occurrence of exception events that have been configured as alarm conditions. These events are from
[Exception Event2]
Note: Changed bit 14 to “NonCnfgAlarm” for firmware version 3.03.
328
Alarm Status 3
Indicates the occurrence of exception events that have been configured as alarm conditions. These events are from
[Exception Event3].
•
Bit 11 “HH HW Ver” indicates a non-configurable High Horsepower hardware version fault.
•
Bit 12 “HH CurUnblnc” indicates a non-configurable High Horsepower output current unbalanced fault.
•
Bit 13 “HH VltUnblnc” indicates a non-configurable High Horsepower Bus voltage unbalanced fault.
•
Bit 14 “HH Bus Data” indicates when
Communication Bus data are mismatched between left side unit and right side unit.
•
Bit 21 “Drive Homing” when the drive is in "Drive Homing" mode (parameter
[Position Control] bit 24 "Find Home" or bit 27 "Return Home" is set to "1")
this alarm is triggered and the drive moves to a home position automatically.
•
Bit 28 “+/- 12v Pwr” identifies when the12V dc control voltage is outside the tolerance range. The positive voltage power e15.50 V dc and the negative
voltage power exceeds -15.50V dc.
•
Bit 29 “AnlgIn1 Loss” indicates a non-configurable Analog Input 1 loss fault.
•
Bit 30 “AnlgIn2 Loss” indicates a non-configurable Analog Input 2 loss fault.
•
Bit 31 “AnlgIn3 Loss” indicates a non-configurable Analog Input 3 loss fault.
Notes: Bits 16, 20 and 23 were added for firmware version 2.04. Bits 11, 12, 13, 29, 30 and 31 were added for firmware version 3.01. Changed bit 21 to “Drive
Homing” and bit 28 to “+/- 12v Pwr” for firmware version 3.03. Bit 14 “HH Bus Data” was added for firmware version 3.04.
No.
Name
Description
Values
Linkab
le
R
ead-Wr
ite
Da
ta
T
ype
Options
AnlgI
n3 Los
s
AnlgI
n2 Los
s
AnlgI
n1 Los
s
N
onC
nf
gA
la
rm
Res
er
ved
Res
er
ved
Res
er
ved
Res
er
ved
N
onC
nf
gA
la
rm
Res
er
ved
N
onC
nf
gA
la
rm
Po
si
t E
rr
-Hr
d Ov
rT
rv
l
+Hrd
Ov
rT
rv
l
-S
ft Ov
rT
rv
l
+Sft
Ov
rT
rv
l
Res
er
ved
N
onC
nf
gA
la
rm
N
onC
nf
gA
la
rm
N
onC
nf
gA
la
rm
N
onC
nf
gA
la
rm
HH PwrBdT
emp
HH PwrEE
E
r
HHPrChrgCntc
HH PwrBd Prc
HH Dr
v
Ovr
ld
HH F
anFdbk
Ls
HH BusWtch
D
g
HH BusC
RC
E
r
HH BusL
in
kLs
HH BusC
omDly
HH In
Phas
eLs
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
No
nCnf
g F
au
lt
Pr
ech
ar
ge Er
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
Iner
tia T
est
No
nCnf
g F
au
lt
No
nCnf
g F
au
lt
Ex
t F
aul
t In
In
v OL
T
rip
In
v OL
P
end
No
n Cn
fg
F
ault
In
v T
empP
end
Mo
to
r St
al
l
Mtr OL P
end
Mtr OL T
rip
No
nCnf
gF
ault
SL
ink
C
omm
No
nCnf
gF
ault
No
nCnf
gF
ault
FB
Opt
1 L
oss
FB
Opt
0
Los
s
Enc
dr1
L
os
s
Enc
dr0
L
os
s
No
nCnf
gF
ault
No
nCnf
gF
ault
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Lg
x LinkC
hng
Lg
x C
lo
sed
Lg
x Timeou
t
Lg
x O
utO
fR
un
N
etL
oss
DPI6
N
etL
oss
DPI5
N
etL
oss
DPI4
N
etL
oss
DPI3
N
etL
oss
DPI2
N
etL
oss
DPI1
D
P
I Los
s P6
D
P
I Los
s P5
D
P
I Los
s P4
D
P
I Los
s P3
D
P
I Los
s P2
D
P
I Los
s P1
N
onCnf
g F
ault
MC
CML
Fa
il
In
te
rp
Syn
ch
E
nab
leHe
alth
R
unt
ime
Da
ta
V
olt
Fdbk
Los
s
B
usUnd
er
V
olt
N
onCnf
g F
ault
Sl
ink Mult
N
onCnf
g F
ault
B
rak
eOL T
rip
N
onCnf
g F
ault
N
onCnf
g F
ault
N
onCnf
g F
ault
MC
Comma
nd
N
onCnf
g F
ault
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Options
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
+/- 1
2v
Pwr
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
Res
er
ve
d
St
ahl Optic
s
Res
er
ve
d
Dr
iv
e Homing
Po
si
t E
rr
-H
rd
Ov
rT
rv
l
+Hrd
Ov
rT
rv
l
-Sf
t Ov
rT
rv
l
+Sft Ovr
Tr
vl
Res
er
ve
d
HH Bus
Da
ta
HH VltU
nb
lnc
HH CurrUnb
lnc
HH HW V
er
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
Non
C
nf
g F
au
lt
HH I
nPhas
eLs
Default
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
0 = False
1 = True
Содержание PowerFlex 700S
Страница 1: ...USER MANUAL Firmware Versions 1 xxx 4 002 PowerFlex 700S High Performance AC Drive Phase II Control ...
Страница 58: ...2 8 Start Up PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 147: ...Programming and Parameters 3 89 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 278: ...D 8 HIM Overview PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 Notes ...
Страница 316: ...Index 6 PowerFlex 700S Phase II AC Drive User Manual Publication 20D UM006G EN P July 2008 ...
Страница 317: ......