99
To remove a measurement from the average calculation, highlight the
measurement using
f
/
g
then press
e
. The check mark next to
the measurement position disappears indicating that the measurement is not
included in calculating the average.
It is not possible to average readings taken before a Move with readings taken
after a Move.
Measurement points, alignment records, and the coupling to sensor distance can be
edited from the measurement table screen. To access these items, press
q
while in
the ‘Measurement table’ screen. Use
f
/
g
to highlight item required from the
context menu that appears.
The context menu items of the “Measurement table” screen are applied to the
measurement currently highlighted on the measurement table.
5.2.2 Measurement history
To help keep measurement and alignment records, use is made of the “Measurement
table” screen context menu item ‘Assign label’. Using this feature, it is possible to
apply labels to particular measurements avoiding confusion when analysing alignment
records.
To assign a label to a measurement, proceed as follows:
1. Access the measurement table from the measurement screen by pressing
q
while in the measurement screen. From the context menu that appears, use
f
/
g
to highlight ‘Table’, then press
e
to confirm selection. Use
f
/
g
to highlight measurement to be assigned a label, confirming by
pressing
e
. A check mark appears next to the measurement.
2. Press
q
then use the navigation keys and highlight ‘Assign label’ from the
context menu that appears.
Note
To remove a measurement from the average calculation, highlight the
measurement using
f
/
g
then press
e
. The check mark next to
the measurement position disappears indicating that the measurement is not
included in calculating the average.
It is not possible to average readings taken before a Move with readings taken
after a Move.
The measurement
table may also be
accessed directly via
the global menu items
Measurement’ ->
‘Measurement table’
Note that the function
‘Assign label’ can be
effected only on checked
measurements.
The measurement table
context menu item ‘Edit
distance’ is used to edit
the dimension coupling
center-to-sensor.
This function makes it
possible to display the
corresponding results
without necessarily having
to remeasure.
Measurement table
Содержание ROTALIGN Ultra iS
Страница 1: ...ROTALIGN Ultra iS Operating handbook Shaft alignment...
Страница 11: ...ROTALIGN Ultra iS Shaft handbook 10 This page intentionally left blank...
Страница 56: ...55 Horizontal shaft alignment 1 2 4 5 6...
Страница 123: ...ROTALIGN Ultra iS Shaft handbook 122 Page intentionally left blank...
Страница 141: ...ROTALIGN Ultra iS Shaft handbook 140 This page intentionally left blank...
Страница 177: ...ROTALIGN Ultra iS Shaft handbook 176 Page intentionally left blank...
Страница 207: ...ROTALIGN Ultra iS Shaft handbook 206 Page intentionally left blank...
Страница 213: ...ROTALIGN Ultra iS Shaft handbook 212 Declaration of conformity...
Страница 219: ...ROTALIGN Ultra iS Shaft handbook 218...