268
Index 6067h
Position window
PP CSP HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
32000
—
—
Immediate
Function code
Mapping
Data type
Accessibility
—
N
DINT32
RW
Index 6068h
Position window time
PP CSP HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
65535
ms
0
Immediate
Function code
Mapping
Data type
Accessibility
—
N
UINT16
RW
Index 606Ch
Velocity actual value
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
—
—
—
—
Function code
Mapping
Data type
Accessibility
—
TPDO
DINT32
RO
Index 606Dh
Velocity window
PV CSV
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
30000
0.1rpm
300
Immediate
Function code
Mapping
Data type
Accessibility
—
N
UINT16
RW
Index 606Eh
Velocity window time
PV CSV
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
65535
ms
0
Immediate
Function code
Mapping
Data type
Accessibility
—
N
UINT16
RW