257
b
A
0
1
Copy function
disabled
enabled
Motor parameter copy
Gain parameter copy
Notch filter paramter copy
B
0
1
disabled
enabled
C
0
1
disabled
enabled
D
0
1
disabled
enabled
Sub-index 2Fh
FPGA software version
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
—
N/A
—
Immediate
Function code
Mapping
Data type
Accessibility
So-46
N
UINT16
RW
For example, 100 is 1.00 version
Sub-index 31h
Motor parameters setting area password
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
9999
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
So-48
N
UINT16
RW
When So-48=1, motor parameter can be set.
Sub-index 32h
Revert to Mfr's value
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1
N/A
0
Restart
Function code
Mapping
Data type
Accessibility
So-49
N
UINT16
RW
Sub-index 33h
Motor overheat protection
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
So-50
N
UINT16
RW
0: disabled 1: enabled