233
0
~
1000
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po234
N
INT16
RW
The compensation for load torque can improve system rigidity. But if the parameter is
set too high, there is noise.
Sub-index 24h
Filter time of load observer PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
30000
0.01ms
1000
Immediate
Function code
Mapping
Data type
Accessibility
Po235
N
INT16
RW
Setting Po235 can compensate load torque, which can improve system rigidity. If the
parameter is set too small, there is noise.
Sub-index 25h
Back EMF compensation coefficient
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1000
0.1%
500
Power on again
Function code
Mapping
Data type
Accessibility
Po236
N
INT16
RW
Sub-index 26h
Target torque range PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
50
1%
2
Immediate
Function code
Mapping
Data type
Accessibility
Po237
N
INT16
RW
Sub-index 27h
Torque filter frequency PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1000
0.1Hz
10
Immediate
Function code
Mapping
Data type
Accessibility
Po238
N
INT16
RW
Sub-index 29h
Center frequency of jitter inhibition
PP PV PT CSP CSV CST HM