265
4
At position reached
P-CMP Position completed
5
At torque limit
T-LT
T-LT is activated when toque is limited.
6
Servo alarm activated
ALM
ALM is activated when the drive has detected a
fault condition.
7
Electromagnetic brake
control
BRAKE BRAKE is activated actuation of motor brake.
8
Overload warning
OL-W
Overload pre-alarm signal
9
At speed limit
S-LT
S-LT is activated when speed is limited.
10
Reserved
Reserved Reserved
11
Large position deviation
pre-warning
PER-W
PER-W is activated when position deviation is
too large.
12
Homing completed
HOME
HOME is activated when the servo drive has
detected that the HOME sensor has been
detected.
13-15 Reserved
Reserved Reserved
16
Dynamic brake
DRN_BR Dynamic brake is valid, output this signal.
8.4 Parameters defined by sub-protocol (6000h)
Index 603Fh
Error code
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
—
—
—
—
Function code
Mapping
Data type
Accessibility
—
TPDO
UINT16
RO
Please refer to 6.1.9.
Index 6040h
Control word
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
65535
—
0
immediate
Function code
Mapping
Data type
Accessibility
—
RPDO
UINT16
RW
Please refer to 7.2.1.