280
Po015
N
DINT32
RW
2)
Inertia identification mode selection
Illustration:
(1) Po008=0
:
Inertia identification is disabled.
(2) Po008=1
:
Offline fwd/rev identification, suitable for the equipment with limit motion range.
(3) Po008=2
:
Offline single direction identification, suitable for the equipment that cannot run
reversely.
(4) Po008=3
:
Online inertia auto identification, servo drive always keeps online auto
identification, if servo drive is jog running, inertia is displayed, not JOG”.
3) Offline inertia identification action gap time
2000h-0Ah
Offline rotational inertia identification action gap time
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1~2000
ms
100
Immediate
Function code
Mapping
Data type
Accessibility
Po009
N
INT16
RW
4) Motor accel/decel time at offline inertia identification
2000h-0Fh
Movement of inertia acele/decel time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
200~5000
ms
1000
Immediate
2000h-09h
Inertia identification mode selection PP PV PT CSP CSV CST HM
Setting Range
Unit
Mfr’s
Value
Effect
0
:
Disabled
1
:
Offline fwd/rev direction
identification.
2: Offline single direction
identification.
3: Online auto inertia identification
N/A
0
Immediate effect
Lost if power’s
off
Function code
Mapping
Data type
Accessibility
Po008
N
INT16
RW