221
Po010
N
INT16
RW
Po010 is used to set servo drive rigidity. Please refer to 9.3.
Sub-index 0Eh
Rotation inertia ratio
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
30000
0.01
200
immediate
Function code
Mapping
Data type
Accessibility
Po013
N
INT16
RW
Please refer to 9.3.
Sub-index 0Fh
Movement of inertia acele/decel time PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
200
~
5000
ms
1000
immediate
Function code
Mapping
Data type
Accessibility
Po014
N
INT16
RW
Please refer to 9.3.
Sub-index 10h
Motion range of off-line inertia recognition
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
200
~(
2
31
-1
)
N/A
—
immediate
Function code
Mapping
Data type
Accessibility
Po015
N
DINT32
RW
Please refer to 9.3.
Sub-index 12h
Z pulse frequency-division output width
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
50
~
30000
N/A
—
immediate
Function code
Mapping
Data type
Accessibility
Po017
N
INT16
RW
Please refer to 7.1.12.
Sub-index 13h
Pulse output configuration
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
Four-parameter
N/A
0001
immediate
Function code
Mapping
Data type
Accessibility