245
Po506
N
INT16
RW
8.3.8 Index segment 2006h (function code Ho
□□□
)
Sub-index 01h
Rated voltage
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
30000
V
—
—
Function code
Mapping
Data type
Accessibility
Ho000
N
UINT16
RO
Sub-index 02h
Rated current
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
30000
0.1A
—
Immediate
Function code
Mapping
Data type
Accessibility
Ho001
N
UINT16
RW
Sub-index 03h
Max rotary speed
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
32000
rpm
—
Immediate
Function code
Mapping
Data type
Accessibility
Ho002
N
UINT16
RW
Sub-index 04h
Rated rotary speed
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
32000
rpm
—
Immediate
Function code
Mapping
Data type
Accessibility
Ho003
N
UINT16
RW
Sub-index 05h
Motor pole pairs
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
30
Pairs
—
Immediate
Function code
Mapping
Data type
Accessibility
Ho004
N
UINT16
RW