FL20-C Series
48
4.1.3
Typical main circuit wiring example
(1)
220V servo main circuit wiring example
:
I
N
O
U
T
Network
interface
Plan form
Port indicator:
IN: EtherCAT from pre-stage network signal input
OUT: EtherCAT to post-stage network signal output
显示
面板
方向
EtherCAT
master station
Alarm relay
RLY normally-
open contact
Contactor KM1
Normally-open
contact
KM1
L1
L2
L3
L1C
L2C
B2
B3
N+
N-
B1
QF circuit breaker
U
V
W
Three-phase AC
220V power supply
*
PE
M
PG
ALM+
ALM-
+24V
0V
Alarm relay
RLY
CN1
CN2
CN3
Contactor
KM1 coil
Manual power on
External resistor
Servo motor
P
E
FIL filter
Manual power off
Panel
orientation
S
e
rv
o
d
ri
v
e
Fig 4.1.7 Typical wiring of 220V servo main circuit
Instructions:
1.
Built-in brake resistor is used by default, B2 and B3 are shorted. If external resistor is need,
remove the jumper between B2 and B3, then connect external resistor between B1 and B2.
2.
RLY: Externally connected alarm signal output relay.
3.
KM1: contactor, select connect or disconnect main circuit power input by manual switch.
4.
If using the absolute encoder multi-circle function, install battery in the side of encoder cable
with battery unit.
Note: emergency stop circuit should be connected in the wiring design of main
circuit. Make sure that stop running of the equipment and cut off the power supply
immediately to avoid the accident.