244
0
~
2
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po503
N
UINT16
RW
0: no calibration 1: odd calibration 2: even calibration
The entry-into-effect time is 1000ms.
Sub-index 05h
Baud rate PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
5
bit/s
2
Immediate
Function code
Mapping
Data type
Accessibility
Po504
N
UINT16
RW
0: 2400 1:4800 2: 9600 3: 19200 4:38400 5: 57600 Please refer to 6.2
Sub-index 06h
Whether communication is valid PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
Two-parameter
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
Po505
N
UINT16
RW
X
Whether Modbus data is allowed to be
witten into servodrive data storage.
0
d
d
Two-parameter mode
1
No
Yes
Y
Whether EtherCAT data is allowed to
be witten into servodrive data storage.
0
1
No
Yes
Please refer to 6.2. The entry-into-effect time is 1000ms.
Sub-index 07h
Time interval of serial data packet PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
-20~2000
0.1rpm
0
Immediate
Function code
Mapping
Data type
Accessibility