183
Home:
home switch
Deceleration point:
home switch
a
)
Deceleration point signal inactive at homing start
H
-L
Home switch
Home switch signal
Motion profile
The ORGP signal is inactive initially. The motor starts homing in positive direction at high
speed. After reaching the rising edge of the ORGP signal, the motor decelerates and changes to
run in negative direction at low speed. After reaching the falling edge of the ORGP signal, the
motor stops.
b
)
Deceleration point signal active at homing start
-L
Home switch
Home switch signal
Motion profile
The ORGP signal is active initially, and the motor directly starts homing in negative direction at
low speed.
After reaching the falling edge of the ORGP signal, the motor stops.
18
)
6098h=20