252
0: servo drive output current.
Servo drive output current corresponding to 10V is set by So-20.
1: servo drive output voltage.
Servo drive max voltage corresponding to 10V is set by So-21.
2: servo motor speed. Max rotation speed corresponding to 10V is set by So-22.
3: Output voltage 0V+offset. Offset voltage is set by So-24.
Sub-index 15h
Servo drive output current corresponding to 10V
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
1000
0.1A
200
Immediate
Function code
Mapping
Data type
Accessibility
So-20
N
UINT16
RW
The entry-into-effect time is 1000ms.
Sub-index 16h
Servo drive max voltage corresponding to 10V
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
500
1V
500
Immediate
Function code
Mapping
Data type
Accessibility
So-21
N
UINT16
RW
The entry-into-effect time is 1000ms.
Sub-index 17h
Max rotation speed corresponding to 10V
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
32000
0.1rpm
30000
Immediate
Function code
Mapping
Data type
Accessibility
So-22
N
UINT16
RW
The entry-into-effect time is 1000ms.
Sub-index 18h
Motor parameter storing location
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
So-23
N
UINT16
RW
0: When servo drive finishes auto-tuning motor parameter, motor parameters are stored
in servo drive.
1: When servo drive finishes studying motor parameter, motor parameters are stored in
encoder. (Only for encoder with EEPROM)