272
Index 6087h
Torque slope
PT
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
65535
0.1ms
—
Immediate
Function code
Mapping
Data type
Accessibility
—
N
UINT16
RW
Index
6091h-01h
Numerator of Gear ratio
PP CSP HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~(
2
31
-1
)
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po344
N
UDINT32
RW
The entry-into-effect time is 100ms
Index
6091h-02h
Denominator of Gear ratio
PP CSP HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~(
2
31
-1
)
N/A
1000
Immediate
Function code
Mapping
Data type
Accessibility
Po346
N
UDINT32
RW
The entry-into-effect time is 100ms
Index 6098h
Homing method
HM
Setting Range
Setting Unit
Mfr’s Value
Effect
-1
~
35
—
0
Immediate
Function code
Mapping
Data type
Accessibility
—
N
INT16
RW
Index
6099h-01h
First Homing speed
HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
20000
0.1rpm
500
Immediate
Function code
Mapping
Data type
Accessibility
Po120
N
UINT16
RW
The entry-into-effect time is 100ms.