263
Setting
value
Function
Name
Instruction
Signal
type
0
Reserved
Reserved
Reserved
1
Alarm reset
AL-RST
A number of faults (Alarms) can
be cleared by activating AL-RST.
Edge
trigger
2~7
Reserved
Reserved
Reserved
8
Gain switchover
GAIN-SEL
Gain switchover
Level
trigger
9
Reserved
Reserved
Reserved
10
Pulse clear
CLR
Position deviation register returns
to 0 at the position mode.
Edge
trigger
11
Command pulse
prohibited
INH-P
External
pulse
command
is
invalid at the position mode.
Level
trigger
12
Emergency stop
ESP
Motor stops urgently.
Level
trigger
13
Reverse run
prohibited
R-INH
Motor is forbidden reverse run.
Level
trigger
14
Forward run
prohibited
F-INH
Motor is forbidden forward run.
Level
trigger
15~21
Reserved
Reserved
Reserved
22
External reference
origin
ORGP
ORGP is external reference
origin.
Edge
trigger
23
Reserved
Reserved
Reserved
24
Reserved
Reserved
Reserved
25
Reserved
Reserved
Reserved
26
Terminal forward
jogging
JOGU
Realized by controlling terminal.
Level
trigger
27
Terminal reverse
jogging
JOGD
Realized by controlling terminal.
Level
trigger
28
Motor overheat
HOT
Realized by controlling terminal.
Level
trigger
29~33
Reserved
Reserved
Reserved
34
Touchprobe-1
Touchprobe-1 Touchprobe-1
Level
trigger
35
Touchprobe-2
Touchprobe-2 Touchprobe-2
Level
trigger
Programmable output terminals include DO1 ~ DO4 (Related parameters are Po421~ Po424),
ALM (Related parameter is Po425).
Servo drive must be restarted after terminal function is set.