Using OmniStream
™
with Velocity
™
Device Manager
99
The Velocity/OmniStream Interface
Stop
Click this drop-down list to select the stop bit:
1
,
1.5
, or
2
.
SAVE
Click this button to save all changes under the
Serial Port
window group.
Serial Configuration window groups
The following fields apply to both
Serial configuration
window groups. The single-channel encoder will only have
one
Serial configuration
window group.
Port
Click this drop-down list to select the desired serial port.
Mode
Click this drop-down list to select the desired control mode. Available values are:
cli
and
tcpproxy
. Decoders
also have an
output
option. Select
tcpproxy
to translate received
IP control traffic to RS-232 output. Selecting
the
cli
option will force the serial port to function as a Command-Line Interface (CLI) for control of the encoder.
Refer to
for more information.
SAVE
Click this button to commit all changes within the
Serial configuration
window group.
Command window groups
By default, window groups for the following commands are created:
Display Off
,
Display On
,
Volume Down
,
and
Volume Up
.
Interpret on
Click this drop-down list to select the endpoint where the command will be processed:
encoder
or
decoder
.
ASCII
Enter the ASCII representation of the command string in this field.
HEX
Enter the hexadecimal representation of the command in this field.
NOTE:
When entering the command string, it is not required to enter the string under both the
ASCII and HEX fields. The encoder requires that one field be completed.
SAVE
Click this button to commit all changes within the
Command
window group.