The Velocity/OmniStream Interface
DSCP
Click this drop-down list to select the DSCP value. Refer to
Differentiated Services Code Point (page 146)
information on this topic.
Bidirectional
Click this toggle switch to enable or disable bidirectional control. When enabled (green), control signals will be able
to pass from encoder to decoder, or from decoder to encoder.
Listen Port
Enter the listening port in this field.
Enable Encoder Group
Click this toggle switch to enable (green) or disable encoder grouping.
Group Name
Enter the name of the encoder in this field. Only available if encoder grouping is enabled.
Active
Indicates if the encoder group is active. If active, then this indicator will be green. Only available if encoder grouping
is enabled.
Trigger
Click this drop-down list to select the trigger type:
manual
or
input connected
. Only available if encoder
grouping is enabled.
Mode
Description
manual
Use this setting to manually enable the input. When set to
manual
, click the
Activate
button to perform the input switching.
input connected
Use this setting to allow the encoder group to use automatic input detection. Once a new
source is connected, that source becomes the active source.
Encoder Groups
ACTIVATE
Click this button to make the encoder video stream the
active
stream for the encoder group.
Members
This field lists all members (encoder IP addresses) that have been added to the group. Use the
Add
button to add
members to the group.
ADD
Click this button to add the IP address of an encoder to the group. Note that when adding encoders to the group,
the IP address of the encoder, which is being used to create the group, must be included.
SAVE
Click this button to commit all changes within the
Stream