L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
58
F49
Current increase and
decrease by single-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by single
clicking of the torch switch. (available when "ON" is
selected in F48)
9
F50
Current increase and
decrease by double-clicking
-100 to 100
0 (A)
Sets current increase/decrease volume by double
clicking of the torch switch. (available when "ON" is
selected in F48)
9
F51
Special crater repeat
OFF/ON
OFF
With the setting of "Crater," sets whether to switch the
welding condition and crater condition by the click
operation of the torch switch:
OFF: not to use torch switch
ON: uses the torch switch
9
F52
Data type of data log
function
0 to 8
0
Sets sample data on the data log:
0: No sampling
1: Welding current / Welding voltage / Sequence
information
2: Current command / Voltage command / Feeding
command
3: Current command / Welding current / Welding
voltage
4: Current command / Welding current / Sequence
information
5: Welding current / Voltage command / Welding
voltage
6: Voltage command / Welding voltage / Sequence
information
7: Welding current / Feeding command / Sequence
information
8: Welding voltage / Feeding command / Sequence
information
-
F53
Sampling speed of data log
function
1/2/3
1
Sets sampling interval of the data log function:
1: 10 ms
2: 100 ms
3: 1 s
-
F54
Tack start process
OFF/ON
OFF
Sets whether to feed the wire with the slowdown speed
at the time of welding start:
OFF: Feeds with slow down speed
ON: Feeds without slow down speed
-
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with automatic machine made by
other manufacturer.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
F60 to
F66
No function
OFF (fixed)
OFF
No functions are provided.
-
F67
Setting change of current value
(initial condition, crater
condition)
OFF/ON
OFF
When “CRATER ON” is selected, sets the current value of
the initial condition and crater condition in the
percentage based on the current value of the welding
condition.
OFF: invalid
ON: settable with percentage
9
F68
Setting of current value (initial
condition)
10 to 300
100 (%)
Sets the current value of the initial condition in the
percentage based on the current value of the welding
condition.
9
F69
Setting of current value (crater
condition)
10 to 300
100 (%)
Sets the current value of the crater condition in the
percentage based on the current value of the welding
condition.
9
F70
Setting of upper limit of analog
remote control
20 to 400
(*1)
400 (A)
Sets the upper limit (the value when the knob is turned
clockwise all the way) of the welding current adjustable
by the analog remote control (optional accessory).
-
20 to 550
(*2)
550 (A)
F71
Interval welding function
OFF/ON
OFF
This function repeats arc ON/OFF to control the heat
input.
9
No.
Function Name
Setting range
Initial value
Explanation
Memory
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...