83
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
)0D[LPXPH[WHUQDOFRPPDQGYROWDJH
When the internal function F4 (Auto/Semi-auto mode) is used with the setting of "1", set the maximum value of command
voltage input from outside.
Select either from 10 V, 14 V, or 15 V.
The below charts show the relationship between current/voltage command voltage and welding current/voltage.
(Use these charts as a rough indication. Welding current/voltage against the welding conditions setting voltage may differ
from the indications on the charts depending on the external input (command voltage), wire length or routing of the cable
at base material side/torch side.)
•
WB-M352
•
WB-M502
)8SVORSHWLPH
When the difference between the initial current and welding current is large, the wire may burn up at the change of the
conditions. In this case, adjust the time period changing from the initial current to the welding current (upslope time)
longer.
•
Setting range of upslope time: 0.0 to 10.0 [sec]
)'RZQVORSHWLPH
When the difference between the welding current and crater current is large, the wire may plunge into weld pool at the
change of the conditions (the wire is fed by inertia because the speed reduction is too late). In this case, adjust the time
period changing from the welding current to the crater current (downslope time) longer.
•
Setting range of downslope time: 0.0 to 10.0 [sec]
0
50
100
150
200
250
300
350
400
0
5
10
15
External command voltage (V)
0
5
10
15
20
25
30
35
40
0
5
10
15
External command voltage (V)
14 V
10 V
15 V
14 V
10 V
15 V
<Command voltage - Welding current characteristic>
<Command voltage - Welding voltage characteristic>
W
e
lding current (A)
W
elding voltage (V)
The minimum value of the voltage for
the welding except TIG welding is 20 A.
10 V
15 V
14 V
0
50
100
150
200
250
300
350
400
450
500
550
10 V
15 V
14 V
0
5
10
15
0
5
10
15
5
10
15
20
25
30
35
40
45
50
0
<Command voltage - Welding current characteristic>
<Command voltage - Welding voltage characteristic>
External command voltage (V)
External command voltage (V)
W
elding current (A)
W
elding voltage (V)
The minimum value of the voltage for
the welding except TIG welding is 20 A.
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...