This section explains about backup of data such as welding conditions and importing of the backup data.
The following contents can be backed up as csv files in USB flash drive and also imported to the welding power source.
Backup data can be used for the following applications.
•
Copying the same setting to another welding power source
•
Analyzing output waveform at the time of failure
•
Managing the error history
T I P S
For the USB flash drive, use the version 1.0. 1.1 or 2.0 with backward compatibility.
The USB flash drive to be used should be formatted as FAT32.
Compatibility of the following USB flash drives has been confirmed.
Model No.: SFU22048E3BP2TO-I-MS-121-STD (swissbit)
Part No.: 100-1820
There is software allowing you to easily display waveforms and edit welding conditions. You
can download it from our home page.
URL: https://www.daihen.co.jp/en/products/welder/software/
6HWWLQJRIZHOGLQJFRQGLWLRQVLQWHUQDOIXQFWLRQV
The following contents can be stored in the "DAIHEN_OTC_WELDING_PRAMETER.CSV" file.
•
All the welding condition data recorded in memory
•
The internal function values at the time of data backup
The right example shows a voltage error. The control No. "P40"
flashes on the left digital meter and the difference between the
average value and specified value "1.5" on the right digital meter, with
the "A" LED lighting.
In case of voltage error, the difference between the average voltage
and specified voltage is displayed in one decimal place.
The display returns to the normal state when any key of the operation
panel is pressed.
If continuous operation is disabled ("1" or "2" is selected) in the "P46"
setting, next welding cannot start until any key of the operation panel
is pressed.
<Example> While welding is conducted with the welding voltage
15 V/Voltage tolerance (+) 0% (=15 V), the average voltage
during welding rose to 16.5 V and the WARNING judgment time
specified in "P45" elapsed.
No.
Data
Backup
Import
1
Welding Condition
Enabled
Enabled
2
Internal function setting
Enabled
Enabled
3
Simplified data log
Enabled
Disabled
4
Failure log
Enabled
Disabled
5
Welding Results Control Function
Enabled
Disabled
CAUTION
The backup data (electronic information) may be altered or lost when affected by static
electricity, impact or repair work. Important information should also be stored as
printed document.
Please note that OTC will not be liable for any alteration or loss of electronic information.
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...