61
Chapter 6
W
elding Condition
F
UNCTION
ON
O
PERATION
P
ANEL
W
ELDING
C
ONDITION
C
HAPTER
6
6HWWLQJVFUHHQ
This section explains the functions of the setting screens displayed on the LCD panel as well as the basic operation
methods.
&RQVWUXFWLRQVDQGVZLWFKLQJRIVHWWLQJVFUHHQ
If the welding power source starts normally, the HOME screen will usually be displayed.
9
Screen operation knob
Used for selecting the functions and changing the settings of the setting screens displayed on the
LCD panel.
10
CONSTANT PENETRATION key
Activates the penetration control. (
6.6.8
-
Penetration control adjustment)
Press this key makes the LED lit, and automatically adjusts the wire feed speed so that the welding
current becomes always constant even with the wire feeding length changed.
This function is available only when the "MILD STEEL CORED", "MILD FLUX CORED", "STAINLESS
STEEL SOLID" or "STAINLESS STEEL CORED" is selected by the WIRE MATERIALS menu.
11
ARC CONTROL key
Set the arc characteristics (soft to hard). (
6.6.7
-
Arc characteristics adjustment)
Pressing this key makes the LED lit, enabling to adjust the arc characteristics by the parameter
adjustment knob. The arc characteristic in adjustment is displayed on the right digital meter.
12
WAVE FRQ key
Not used on this model.
13
EN ratio key
Not used on this model.
14
WIRE INCH key
Feeds the wire. (
5.4
-
Wire Inching)
The LED lights during when the key is pressing, allowing the wire to be fed.
The feeding speed can be adjusted by the parameter adjustment knob.
When the analog remote control (optional) is connected, the speed can be adjusted by the welding
current setting knob.
15
GAS CHECK key
Discharges the shield gas. (
5.3
-
Power ON and Gas Supply)
Pressing this key makes the LED lit, allowing the shield gas to be discharged.
After discharging the gas for approximately 2 minutes automatically stops the discharge.
Pressing this key again lights off the LED, stopping the shield gas discharge.
16
TORCH key
Select air-cooled welding torch or water-cooled welding torch to be used. Switching the mode is
enabled by pressing the key.
•
When the LED is ON: water-cooled welding torch mode
•
When the LED is OFF: air-cooled welding torch mode
17
Terminals for service use
Terminals for the OTC service use.
18
USB connector
For variety of registered data, writes to or reads from the USB memory. (
Chapter 7
-
Administrator
Functions)
No.
Name
Function
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...