S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
96
)6HWWLQJRIFXUUHQWYDOXHLQLWLDOFRQGLWLRQ
The current value of the initial condition can be set in percentage based on the current value of the welding condition.
•
Setting range of current value (initial condition): 10 % to 300
%
)6HWWLQJRIFXUUHQWYDOXHFUDWHUFRQGLWLRQ
The current value of the crater condition can be set in percentage based on the current value of welding condition.
•
Setting range of current value (crater condition): 10 % to 300 %
)6HWWLQJRIXSSHUOLPLWRIDQDORJUHPRWHFRQWURO
Sets the upper limit (the value when the knob is turned clockwise all the way) of the welding current adjustable by the
analog remote control (optional accessory).
If it is difficult to perform fine current adjustment with the knob of the analog remote control when welding in the low
current region, fine current adjustment will be easier if this function is used to lower the upper limit.
•
The setting range is as follows.
WB-M352: 20 to 400 A
WB-M502: 20 to 550 A
),QWHUYDOZHOGLQJIXQFWLRQ
This function repeats arc ON/OFF to control the heat input.
•
“ON”: Enables the function. When this function is enabled, “: Interval” will be displayed at the end of CRATER-FILL
CONDITION in the HOME screen, and internal functions F72 and F73 will be enabled.
(Example) CRATER OFF: Interval
•
“OFF”: Disable the function.
T I P S
• When this function is set to “ON”, the setting of “CRATER-FILL: OFF” will be selected
automatically, disabling other welding modes. (The CRATER-FILL menu will not function.)
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or "5" (Loading
welding condition).
)6HWWLQJDUF21WLPH,QWHUYDOIXQFWLRQ
Sets the arc-ON time in the Interval welding function.
•
Set the arc-ON time in the range of 0.20 to 9.99 seconds.
)6HWWLQJDUF2))WLPH,QWHUYDOIXQFWLRQ
Sets the arc-OFF time in the Interval welding function.
•
Set the arc-OFF time in the range of 0.20 to 9.99 seconds.
):HOGLQJUHVXOWFRQWUROIXQFWLRQLGHQWLILFDWLRQQXPEHUV
Sets the identification numbers of welding power source when using welding result control function. The identification
number set in this function become the part of file name when backing up the data of welding result control function.
(
7.3.4
-
Welding Result Control Function)
•
Setting range of identification number: 1 to 999.
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...