35
Chapter 4
Connection
C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
•
WB-M502
1.
Remove the output terminal cover.
2.
Connect the power cable for base metal side to the output terminal (base metal side) and base metal.
●
At the welding power source side, remove the fixing screws of the output terminals. Fix firmly the round
terminals of the power cable for base metal side with the fixing screws.
3.
Connect the power cable for welding electrode holder side to the output terminal (torch side).
●
Connect the connectors as same as above.
4.
Restore the output terminal cover.
Output terminal cover
Output terminal
(Torch side)
Output terminal
(Base metal side)
Welding
power source
Power cable for
base metal side
Base metal
Power cable for
welding electrode holder side
Welding electrode
holder
Ground a base metal if
required by local law.